Click OK to remain on the page to perform more storage configuration operations.
Click Pending Operations to view the pending operations for the device. Until the job is created
on the selected controller, these pending operations are not applied.
If the pending operation is not created successfully and if there are no existing pending operations,
then an error message is displayed.

Case 4: Selected Add to Pending Operations and there are prior existing

pending operations

If you have selected Add to Pending Operations and then clicked Apply, first the pending operation is
created for the selected storage configuration operation.
If the pending operation is created successfully and if there are existing pending operations, then an
information message is displayed:
Click OK to remain on the page to perform more storage configuration operations.
Click Pending Operations to view the pending operations for the device.
If the pending operation is not created successfully and if there are existing pending operations, then
an error message is displayed.
Click OK to remain on the page to perform more storage configuration operations.
Click Pending Operations to view the pending operations for the device.
NOTE:
At any time, if you do not see the option to create a job on the storage configuration pages, go
to Storage OverviewPending Operations page to view the existing pending operations and
to create the job on the required controller.
Only cases 1 and 2 are applicable for PCIe SSD. You cannot view the pending operations for
PCIe SSDs and hence Add to Pending Operations option is not available. Use racadm command
to clear the pending operations for PCIe SSDs.
Blinking or Unblinking Component LEDs
You can locate a physical disk, virtual disk drive and PCIe SSDs within an enclosure by blinking one of the
Light Emitting Diodes (LEDs) on the disk.
You must have Login privilege to blink or unblink an LED.
The controller must be real-time configuration capable. The real-time support of this feature is available
only in PERC 9.1 firmware and later.
NOTE: Blink or unblink is not supported for servers without backplane.

Blinking or Unblinking Component LEDs Using Web Interface

To blink or unblink a component LED:
1. In the iDRAC Web interface, go to any of the following pages as per your requirement:
OverviewStorageIdentify - Displays the Identify Component LEDs page where you can
blink or unblink the physical disks, virtual disks, and PCIe SSDs.
OverviewStoragePhysical Disks Identify– Displays the Identify Physical Disks page
where you can blink or unblink the physical disks and PCIe SSDs.
247