Viewing Universal Slots

Setting SGPIO Mode

Configuring Backplane Mode

The 13th generation Dell PowerEdge servers supports a new internal storage topology, where two storage controllers (PERCs) can be connected to a set of internal drives through a single expander. This configuration is used for high performance mode with no failover or High Availability (HA) functionality. The expander splits the internal drive array between the two storage controllers. In this mode, virtual disk creation only displays the drives connected to a particular controller. There are no licensing requirements for this feature. This feature is supported only on a few systems.

Backplane supports two modes:

Unified mode — The primary PERC controller has access to all the drives connected to the backplane even if a second PERC controller is installed.

Split mode — One controller has access to the first 12 drives and the second controller has access to the last 12 drives. This splitting is not configurable. The drives connected to the first controller are numbered 0-11 while the drives connected to the second controller are numbered 12-23.

By default, it is in unified mode.

iDRAC allows the split mode setting if the expander has the capability to support the configuration. You may want to enable this mode prior to installing the second controller. iDRAC performs a check for expander capability prior to allowing this mode to be configured and does not check whether the second PERC controller is present.

To modify the setting, you must have Server Control privilege.

If any other RAID operations are in pending state or any RAID job is scheduled, you cannot change the backplane mode. Similarly, if this setting is pending, you cannot schedule other RAID jobs.

NOTE:

Warning messages are displayed when the setting is being changed as there is a possibility of data loss.

LC Wipe or iDRAC reset operation does not change the expander setting for this mode.

This operation is supported only in real-time and not staged.

Any change in this setting only takes effect after a system power reset. If you change from Split mode to Unified, an error message is displayed on the next boot as the second controller does not see any drives. Also, the first controller will see a foreign configuration. If you ignore the error, the existing virtual disks are lost.

Configuring Backplane Mode Using Web Interface

To configure backplane mode using iDRAC Web interface:

1.In the iDRAC Web interface, go to Overview Storage Enclosures Setup The Enclosure Setup page is displayed.

2.From the Controller drop-down menu, select the controller to configure its associated enclosures.

3.In the Value column, select the required mode for the required backplane or enclosure:

• Unified

240

Page 240
Image 240
Dell iDRAC8 manual Configuring Backplane Mode Using Web Interface