sFlow Commands 1211
Default Configuration
No receivers are configured by default.
The default IP address is 0.0.0.0
The default maximum datagram size is 1400.
The default owner string is the empty string.
The default receiver timeout is 0.
The default port is 6343.
Command Mode
Global Configuration mode.
User Guidelines
This command has no user guidelines
Example
console(config)#sflow 1 destination owner 1 timeout
2000
console(config)#sflow 1 destination maxdatagram 500
console(config)#sflow 1 destination 30.30.30.1 560

sflow polling

Use the sflow polling command to enable a new sflow poller instance for this
data source if rcvr_idx is valid. Use the “no” form of this command to reset
poller parameters to the defaults.
Syntax
sflow

rcvr-index

polling ethernet
interfaces

poll-interval

no sflow

rcvr-index

polling ethernet
interfaces
rcvr-index
The sFlow Receiver associated with the poller (Range: 1–8).