Using the CLI 183
Management Standby Preconfig Plugged-in Switch Code
SW Status Status Model ID Model ID Status Version
---- --------- -------- ---------- ------------ --------- --------
1 Mgmt Sw PC6224 PCT6224 OK 3.2.1.3
console>
Boot Utility Menu
If a user is connected through the serial interface during the boot sequence,
pressing the <esc> key interrupts the boot process and displays a Boot Utility
Menu. Selecting item 2 displays the menu and may be typed only during the
initial boot up sequence. When the system boot up is complete, typing the
escape sequence

does not

display the menu.
Reloading all switches.
Boot code......
Boot Menu Version: 3.2.0.1
Select an option. If no selection in 10 seconds then
operational code will start.
1 - Start operational code.
2 - Start Boot Menu.
Select (1, 2):2
The Boot Utility Menu offers the following options:
1 - Start operational code
2 - Change baud rate
3 - Retrieve event log using XMODEM
4 - Load new operational code using XMODEM
5 - Display operational code vital product data
6 - Abort code update
7 - Update boot code