Alert! Unsupported Processor Type Detected. System Halted! — Replace the microprocessor. See "Microprocessor."

Alert! Uncorrectable Memory Error Previously Detected... Address xxxxxxxxh — One or more memory modules may be improperly seated or faulty or the system board may be faulty. See "Memory Problems" and "System Board Problems."

Attachment failed to respond — The floppy or hard drive controller cannot send data to the associated drive. See "Floppy drive problems" or "Hard drive problems" for troubleshooting suggestions.

Bad command or file name — Ensure that you have spelled the command correctly, have put spaces in the proper place, and have used the correct pathname.

Bad error-correction code (ECC) on disk read — The floppy or hard drive controller detected an uncorrectable read error. See "Floppy drive problems" or "Hard drive problems" for troubleshooting suggestions.

Controller has failed — The hard drive or the associated controller is defective. See "Floppy drive problems" or "Hard drive problems" for troubleshooting suggestions.

Data error — The floppy or hard drive cannot read the data.

For the Microsoft® Windows® operating system, run the chkdsk utility to check the file structure of the floppy or hard drive.

For another operating system, run the appropriate corresponding utility.

See your operating system documentation for information on running these utilities.

Decreasing available memory — One or more memory modules might be faulty or improperly seated.

Reinstall the memory modules and, if necessary, replace them.

See "Memory Problems" for additional troubleshooting suggestions.

Diskette drive 0 seek failure — A cable might be loose or the computer configuration information may not match the hardware configuration. See "Floppy drive problems" for troubleshooting suggestions.

Diskette read failure — The floppy disk may be defective or a cable might be loose.

If the drive access light turns on, try a different disk.

See "Floppy drive problems" for troubleshooting suggestions.

Diskette subsystem reset failed — The floppy drive controller might be faulty. Run the Dell Diagnostics.

Diskette write protected — The floppy disk is write-protected. Slide the write-protect notch to the open position.

Drive not ready — No floppy disk is in the drive. Put a floppy disk in the drive.

Gate A20 failure — One or more memory modules might be faulty or improperly seated.

Reinstall the memory modules and, if necessary, replace them.

See "Memory Problems" for additional troubleshooting suggestions.

Hard-disk configuration error —

Hard-disk controller failure —

Hard-disk drive failure —

The hard drive failed initialization.

Run the Dell Diagnostics.

See "Hard drive problems" for troubleshooting suggestions.

Insert bootable media — The operating system is trying to boot to a nonbootable floppy disk or CD. Insert a bootable floppy disk or CD.

Invalid configuration information - please run SETUP program — The computer configuration information does not match the hardware configuration. Enter system setup and correct the computer configuration information.

Keyboard Controller Failure —

KeyBoard Stuck Key Failure —

Keyboard failure —

A cable or connector might be loose, or the keyboard or keyboard/mouse controller might be faulty. See "Keyboard Problems."

Memory address line failure at address, read value expecting value A memory module might be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them. See "Memory Problems" for additional troubleshooting suggestions.

Memory allocation error — The software you are attempting to run is conflicting with the operating system, another program, or a utility.

1.Turn off the computer, wait 30 seconds, and then restart the computer.

2.Try to run the program again.

3.If the error message appears again, see the software documentation for additional troubleshooting suggestions.

Memory data line failure at address, read value expecting value

Memory double word logic failure at address, read value expecting value

Memory odd/even logic failure at address, read value expecting value

Page 139