Riser | PCIe slot | Processor | Height | Length | Link width | Slot width | |
|
|
| connection |
|
|
|
|
|
|
|
|
|
|
|
|
1 |
| 3 | Processor 2 | Low Profile | Half Length | x8 | x16 |
2 |
| 4 | Processor 2 | Full Height | Full Length | x16 | x16 |
2 |
| 5 | Processor 1 | Full Height | Full Length | x8 | x16 |
3 | (default) | 6 | Processor 1 | Full Height | Full Length | x8 | x16 |
3 | (alternate) | 6 | Processor 1 | Full Height | Full Length | x16 | x16 |
3 | (default) | 7 | Processor 1 | Full Height | Full Length | x8 | x16 |
NOTE: To use PCIe slots 1 through 4 on the riser, both the processors must be installed.
NOTE: The
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All other expansion cards should be installed in card priority and slot priority order.
Table 4. Expansion card installation order
Card | Card type | Slot priority | Max allowed | ||
priority |
|
|
|
|
|
| PowerEdge | PowerEdge | PowerEdge | PowerEdge | |
|
| ||||
|
| R730 | R730xd | R730 | R730xd |
|
|
|
|
|
|
1 | PCIe Bridge | not supported | 4 | 0 | 1 |
2 | GPU (double wide) | 6, 4 | not supported | 2 | 0 |
| GPU (single wide) | 6, 4, 7, 5 | not supported | 4 | 0 |
3 | RAID H730P (low profile) | not supported | 3, 2 | 0 | 1 |
4 | RAID H830 | 7, 6, 4, 5 | 6, 4, 5 | 2 | 2 |
| RAID H830 (low profile) | 3, 2 | 3, 2 | 2 | 2 |
5 | 40 Gb NICs (full height) | 5, 7, 4, 6 | 4, 6, 5 | 4 | 3 |
| 40 Gb NICs (low profile) | 3, 2, 1 | 3, 2, 1 | 3 | 3 |
6 | FC16 HBA (full height) | 5, 7, 4, 6 | 4, 6, 5 | 4 | 3 |
| FC16 HBA (low profile) | 2, 3, 1 | 2, 3, 1 | 3 | 3 |
7 | 10 Gb NICs (full height) | 5, 7, 4, 6 | 4, 6, 5 | 4 | 3 |
| 10 Gb NICs (low profile) | 2, 3, 1 | 2, 3, 1 | 3 | 3 |
8 | FC8 HBA (full height) | 5, 7, 4, 6 | 4, 6, 5 | 4 | 3 |
| FC8 HBA (low profile) | 2, 3, 1 | 2, 3, 1 | 3 | 3 |
9 | 1 Gb NICs (full height) | 5, 7, 4, 6 | 4, 6, 5 | 4 | 3 |
| 1 Gb NICs (low profile) | 2, 3, 1 | 2, 3, 1 | 3 | 3 |
10 | 12 Gb SAS (low profile) | 3, 2, 1 | 3, 2, 1 | 3 | 3 |
97