Table 4-8. Severity Options

Option

Description

 

 

Informational

Select the check boxes in this column to cause the DRAC 4 to send an alert if

 

the corresponding event listed under Alert Description occurs with a severity

 

of Informational (lowest severity).

Warning

Select the check boxes in this column to cause the DRAC 4 to send an alert if

 

the corresponding event listed under Alert Description occurs with a severity

 

of Warning (medium severity).

Severe

Select the check boxes in this column to cause the DRAC 4 to send an alert if

 

the corresponding event listed under Alert Description occurs with a severity

 

of Severe (highest severity).

Alert Description

Lists the following events monitored by the DRAC 4. An alert (specified as

 

either informational, warning, or severe) is sent when the event is triggered at

 

the level of severity you selected in the check boxes to the left.

 

NOTE: For information about how to manage events, see the

 

Server Administrator User's Guide.

 

Select All — Monitors all of the sensors available on the system.

 

System Temperature Sensors — Monitors the temperature sensors on the system.

 

System Voltage Sensors — Monitors the voltage sensors on the system.

 

System Fan Sensors — Monitors the system fan speed (RPM).

 

System Miscellaneous Sensors — Monitors other available system sensors

 

such as chassis intrusion.

 

 

Viewing Information About Existing Alerts

Click an alert in the SNMP Alert List to display the properties for existing SNMP alerts. See Table 4-9 for descriptions.

NOTE: During the first 40 seconds after a DRAC 4 reset, the DRAC 4 is synchronizing with the system BMC and the managed system service. If an alert is generated during this time, some of the values may be reported as "unknown." The time field contains the number of seconds since DRAC 4 startup.

After synchronization has completed, all values are reported correctly.