Description

The racdump subcommand provides a single command to get dump, status, and general DRAC 4 board information.

The following commands are executed as a result of the single racdump subcommand:

getsysinfo

coredump

memmap

netstat

getssninfo

Output

The output of the individual commands are displayed.

racreset

NOTE: To use this command, you must have Configure DRAC 4 permission.

Table A-24 describes the racreset subcommand.

Table A-24. racreset

SubcommandDefinition

racreset

Resets the DRAC 4.

 

 

NOTICE: You must wait until the DRAC 4reset is completed before issuing another command. If the

DRAC 4 reset is not completed, you may receive the following error: racadm <command name>

Transport: ERROR: (RC=-1)

Synopsis

racadm racreset [hard soft graceful] [delay in seconds]

Description

The racreset subcommand issues a reset to the DRAC 4. The user is allowed to select how many seconds of delay occur before the reset sequence is started. The reset event is written into the DRAC 4 log.

The default option is soft. If you do not type an option, the racadm CLI waits three seconds and then runs the soft option with the racreset subcommand.

NOTICE: You must reboot your system after performing a hard reset of the DRAC 4 as described in Table A-25.