NANO-PV-D510A User Manual

Parallel Port Address [Disabled]

Use the Parallel Port Address option to select the parallel port base address.

Disabled DEFAULT No base address is assigned to the Parallel Port

378

Parallel Port I/O port address is 378

278

Parallel Port I/O port address is 278

3BC

Parallel Port I/O port address is 3BC

Parallel Port Mode [Normal]

Use the Parallel Port Mode option to select the mode the parallel port operates in.

Normal

DEFAULT

The normal parallel port mode is the standard mode

 

 

for parallel port operation.

Bi-directional

 

Parallel port outputs are 8-bits long. Inputs are

 

 

accomplished by reading 4 of the 8 bits on the

 

 

status register.

EPP

 

The parallel port operates in the enhanced parallel

 

 

port mode (EPP). The EPP mode supports

 

 

bi-directional communication between the system

 

 

and the parallel port device and the transmission

 

 

rates between the two are much faster than the

 

 

Normal mode.

ECP

 

The parallel port operates in the extended

 

 

capabilities port (ECP) mode. The ECP mode

 

 

supports bi-directional communication between the

 

 

system and the parallel port device and the

 

 

transmission rates between the two are much faster

 

 

than the Normal mode

Page 77

Page 91
Image 91
Dialogue Tech NANO-PV-D510A user manual 3BC, Epp, Ecp