iQSeries, Ultrasonic Hand Held Systems User’s Manual

AC Power Requirements

 

System

 

 

Overload

 

North America/

Operating

Generator

Probe

Power

Input AC Power Requirements

Model

Japan

Frequency

Model Number

Part Number

Rating

Nominal AC Volt

Number

AC Outlet Rating

 

 

 

(Watts)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20kHz

HP 2.61-P

20HP060-1E

41PG20S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

20kHz

HP 2.61-H

20HP060-1E

41HP20S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

20kHz

HP 2.62-P

20HP060-2E

41PG20S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

20kHz

HP 2.62-H

20HP060-2E

41HP20S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

30kHz

HP 3.61-H

30HP060-1E

41HP30S

600

100-120 VAC, 50/60 Hz @ 9.0 Amps

15.0 Amps

 

 

 

 

 

30kHz

HP 3.62-H

30HP060-2E

41HP30S

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

 

40kHz

HP 4.61-P

40HP060-1E

41PG40S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

40kHz

HP 4.61-H

40HP060-1E

41HP40S

 

100-120 VAC, 50/60 Hz @ 9.0 Amps

 

 

 

 

 

 

 

 

40kHz

HP 4.62-P

40HP060-2E

41PG40S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

40kHz

HP 4.62-H

40HP060-2E

41HP40S

 

200-240 VAC, 50/60 Hz @ 4.5 Amps

 

 

 

 

 

 

 

 

Table 9- IAC Power Requirements

Page  60

Dukane Manual Part No. 403-577-01

Page 66
Image 66