Section 6 – Probes and Probe Stacks

6.Thread the components together and tighten to the following torque specifications using only the correct size wrenches. Use spanner wrenches on components with spanner wrench holes or an open end wrench on components with wrench flats. See Figure 6–5 for the correct procedure. Refer to Table 6-III for torque unit conversions. Be careful not to overtighten.

In-lb

Ft-lb

N-m

kHz

 

 

 

 

540

45

61

15 kHz stack

 

 

 

 

420

35

47.5

20 kHz stack

 

 

 

 

216

18

24.4

30 kHz stack

 

 

 

 

216

18

24.4

40 kHz stack

 

 

 

 

Table 6-IIIHorn/Booster Torque Unit Conversions

NOTE

Horn and booster torque specifications are higher than stud torque specs. Be sure to tighten the horn or booster joints to the higher torque limits.

Do not tighten the studs to these higher ratings as it may induce unnecessary stress in the assembly.

Dukane Manual Part No. 403-577-01

Page  41

Page 47
Image 47
Dukane iQ Series user manual In-lb Ft-lb KHz