iQSeries, Ultrasonic Hand Held Systems User’s Manual

Setup Maintenance

Introduction

The screens available in Setup Maintenance allow the operator to Load, Store, or Delete generator weld setups. As many as eight (8) setups can be loaded and stored for your convenience.

Navigating

1.When the SETUP key is pressed for the first time, the display looks like Figure 5-18. This screen indicates that Setup #1 is Empty. Because there is not yet any data available, this setup has nothing in it, and is empty. You will see that Load is highlighted.

Press ENTER.

2.Load - (Load means to put data into the generator’s memory, or to program a setup.)

A pop-up screen asks if defaults should be loaded for Setup #1. See Figure 5-18A.

Select NO, and the display will change to an Operate screen.

Select YES, and Manual Weld shows at the top of the Operate screen that will display next. The setup number appears in the lower left corner of the screen. Refer to Figure 4-4.

3.After selecting YES, press SETUP, and the display will look like Figure 5-19.

4.Store - (Store means to save the setup data.) Tap the right arrow key once to highlight Store. See Figure 5-20.

5.Press ENTER, and a pop-up screen as shown in Figure 5-21 appears.

6.Select YES if you want to overwrite (replace) whatever is in the setup, and select NO if you do not want to change anything for that setup.

Press the ENTER key to save your selection.

7.Delete -To delete the setup, select Delete as shown in Figure 5-22, and press the ENTER key. A pop-up screen appears to ask you to confirm your choice.

Select YES or NO, and press ENTER again.

Continued

Setup Maintenance

Load

 

Store

Delete

Setup #

 

 

 

1

EMPTY

 

 

 

 

 

Figure 5-18Setup Maintenance - 1

Setup #1 Empty

Load Defaults?

YES NO

Figure 5-18APop-up Load Defaults?

Setup Maintenance

Load

 

Store

Delete

Setup #

 

Mode: Manual

1

T: 0.000 S

 

A: 100%

E: 0 J

 

H: 0.0 S

Figure 5-19Setup Maintenance - 2

Setup Maintenance

Load

 

Store

Delete

Setup #

 

 

Mode: Manual

1

T: 0.000 S

 

A: 100%

E: 0 J

 

H: 0.0 S

Figure 5-20Setup Maintenance - 3

Overwrite

Setup #1?

YES NO

Figure 5-21 Pop-up Overwrite Setup?

Setup Maintenance

Load

Store

 

Delete

Setup #

 

Mode: Manual

1

T: 0.000 S

 

A: 100%

E: 0 J

 

H: 0.0 S

Figure 5-22Setup Maintenance - 4