Section 10 – I/O Interface
Page  65
Dukane Manual Part No. 403-577-01
HAND PROBE
OUTPUTS
0V 1 2 3

iQ Hand Probe Generator

Rear Panel Detail

X 1

X 2

To OUTPUTS:
1, 2, or 3
Provided by Customer
Status
Indicator or
Audible
Alarm
(333mA
maximum)

+

_

NOTE
0V
(Output
Common)
is
connected
to
Chassis
Ground
(Earth).
Power Supply
0V
+ 24 V
+ 30 VDC Maximum
Figure 10-1 OUTPUTS Connection Example