Section 3 – Installation

Power Cords

200/240 Volt Systems

The IEC AC power inlet connector mounted on the rear panel requires a properly configured IEC compliant power cord.

The 200/240 AC power cords supplied with the generators are matched to the ultrasonic output power rating and the continent of specified use. See Table 3-I.

Continent of Use

Power Cord

Power

 

Part Number

 

 

 

 

North America

200 - 1541

240V, 10A

 

 

 

Europe

200 - 1542

240V, 10A

 

 

 

India

200 - 1624

240V, 10A

 

 

 

Table 3- IStandard IEC AC Power Cord Part Numbers

100/120 Volt Systems (North America or Japan) The power cord (including strain relief) supplied with the 100/120 AC systems is permanently attached to the rear of the generator. Units with this power cord are for use in North America or Japan.

HAND PROBE Connector

Ultrasound Output

The ultrasound output connector used with this generator is integrated into a D-Sub style connector. This connector provides superior shielding of electrical noise. The output connector mates with a fully shielded ultrasound cable that is secured to the generator with two simple, reliable thumbscrews.

The ultrasonic output from this connector (that drives the attached ultrasonic load) is a very high AC voltage.  At high power levels there is high current, and the cable must be securely attached to the hand probe for safe operation. Only use original equipment ultrasound cables for safe and reliable system operation.