PowerH SERIES
H5000 | Umains in V | Imains in A | Pmains in W | Pout in W | Pd in W1 | BTU/hr2 |
Idle | 230 | 0.7 | 78 | - | 78 | 266 |
Max. Output Power @ 8 Ω3 | 230 | 24.5 | 4089 | 2 x 1500 | 1089 | 3716 |
Max. Output Power @ 4 Ω3 | 230 | 40.9 | 7137 | 2 x 2500 | 2137 | 7292 |
1/3 Max. Output Power @ 4 Ω3 | 230 | 18.1 | 2927 | 2 x 833 | 1260 | 4300 |
1/8 Max. Output Power @ 4 Ω3 | 230 | 6.2 | 877 | 2 x 313 | 252 | 860 |
1/8 Max. Output Power @ 4 Ω4 | 230 | 9.6 | 1450 | 2 x 313 | 806 | 2750 |
1/8 Max. Output Power @ 4 Ω4 5 | 253 | 11.6 | 1944 | 2 x 378 | 1188 | 4053 |
Normal Mode | 230 | 9.2 | 1368 | 2 x 250 | 868 | 2962 |
Rated Output Power (0 dB) @ 4 Ω3 | 230 | 37.5 | 6445 | 2 x 2100 | 2245 | 7660 |
Alert (Alarm) Mode | 230 | 22.7 | 3760 | 2 x 1050 | 1660 | 5664 |
Max. Output Power @ 2 Ω3 | 230 | 44.3 | 8180 | 2 x 3500 | 1180 | 4026 |
1/8 Max. Output Power @ 2 Ω3 | 230 | 15.3 | 2427 | 2 x 438 | 1552 | 5296 |
1/8 Max. Output Power @ 2 Ω4 | 230 | 13.6 | 2105 | 2 x 438 | 1230 | 4197 |
1.Pd = Verlustleistung
2.1BTU = 1055.06 J = 1055.06 Ws 3.Sinusaussteuerung (1 kHz)
4.Rosa Rauschen gemäß EN60065 / 7. Edition 5.10% Netzüberspannung
Die Stromaufnahmen für andere Netze können mit folgenden Faktoren direkt proportional umgerechnet werden: 100 V = 2.3, 120 V = 1.9, 220 V = 1.05, 240 V = 0.97.
2.3 Netzschalter
Der Netzschalter an der Frontseite trennt die Endstufe von der Netzversorgung. Durch Drücken des Netzschalters wird das Hochfahren der Endstufe gestartet. Eine Softstart- Schaltung vermeidet dabei Einschaltstromspitzen auf der Netzleitung. Dadurch wird verhindert, dass der Leitungsschutzschalter des Stromnetzes beim Einschalten der Endstufe anspricht.
Die Lautsprecher werden über die Ausgangsrelais um ca. 2 Sekunden verzögert zugeschaltet. Hierdurch werden etwaige Einschaltgeräusche effektiv unterdrückt, die ansonsten in den Lautsprechern hörbar wären. Während dieser Verzögerung leuchtet die