PowerH SERIES

RCM-26

NETWORK AND GENERAL FEATURES

Remote Control and Software

IRIS-Net™, Multiple PCs possible, MS Windows 98, 2000, XP

 

 

Maximum Configuration

250 Amplifiers in total, 100 Amplifiers per CAN bus, 2000 meter cable run

 

 

Supervised Amplifier Parameters

Operation mode, temperature, output voltage and current, impedance of connected speakers,

 

protection mode status, mains voltage and current, power consumption, pilot tone detection

 

 

Network Supervision

CAN bus failures, defective or missing amplifiers, bandwidth, failure protocol and messaging

 

 

Audio Monitoring

All input and output signals

 

 

AUDIO SPECIFICATIONS

 

Analog Audio Input

2 audio inputs on internal slot connector, pre-/post fader selectable

 

 

Input Level (nominal)

+6 dBu / 1.55 V

 

 

Input Level (max. before clip)

+21 dBu / 8.7 V

 

 

A/D Conversion

24 Bit linear, Sigma-Delta, 128 times over-sampling

Digital Audio Input

AES3 (AES/EBU) format, XLR In/Thru connectors

 

 

Input Sample Rates

32 kHz...192 kHz, internal Sample-Rate-Converter

 

 

Audio Output

2 audio outputs on internal slot connector

Output Level (nominal)

+6 dBu / 1.55 V

 

 

Output Level (max. before clip)

+21 dBu / 8.7 V

 

 

D/A Conversion

24 Bit, Sigma-Delta, 128 times over-sampling

Monitor Outputs

2 x RJ-45 (REMOTE), electronically symmetric (Pins 7/8)

 

 

Frequency Response

20 Hz...40 kHz (-1.0 dB)

 

 

Signal to Noise Ratio (A-weighted)

ADC: 120 dB typical

 

DAC: 118 dB typical

 

AES3: 128 dB typical

 

Analog In to Analog Out: 116 dB typical

 

 

THD+N

< 0.005%

 

 

Signal Delay

1.031 ms @ 96 kHz

 

 

Crosstalk

< -110 dB @ 1 kHz

SIGNAL PROCESSING

 

Sample Rate

96 kHz (48 kHz optional)

 

 

Data Format

24 Bit linear A/D and D/A conversion, 48 Bit processing

Signal Processing

2 DSPs (150 MHz, 300 MIPS)

 

 

Master EQ (Input)

6 filters per channel, selectable as PEQ, Lo-Shelf, Hi-Shelf, Hi-Pass and Lo-Pass

 

 

Master Delay (Input)

2...2000 ms per channel (units: µs, ms, m, inches, feet, samples)

Channel EQ (Output)

6 filters per channel, selectable as PEQ, Lo-Shelf, Hi-Shelf, Hi-Pass, Lo-Pass and All-Pass

 

 

X-Over

Hi-Pass and Lo-Pass per channel, 6/12/18/24 dB Bessel/Butterworth, 12/24 dB Linkwitz-Riley

 

 

FIR Filters

Zero-Latency Processing, Linear Phase X-Over

Dynamics

Compressor and Limiter per channel

 

 

Other Functions

Input Routing, Level, Mute, Polarity, Sine and Noise Generator, Pilot Generator, Level Meters

 

 

Protection

Digital Speaker Protection

INTERFACES

 

CAN

10...500 kbaud, 2 x RJ-45 (IRIS-Net™ Control)

 

 

RS-232

9pin DSUB female (Multi-Media Control)

GPIO Control Port

1 x 6-pole Euro block

 

2 Control Inputs

 

2 Control Outputs

 

2 Reference Outputs (+5 V, 200 mA / GND)

 

 