Dynacord H 2500, H 5000 owner manual Installation Notes, IRIS-Net

Models: H 2500 H 5000

1 144
Download 144 pages 16.51 Kb
Page 36
Image 36

PowerH SERIES

the digital audio input offers a dynamic range of 128 dB. Using the analog audio input offers a dynamic range of 120 dB, which, by the way, is an absolute peak value for digital audio devices.

For further details about configuration, control and monitoring of amps with installed RCM-26 modules, please refer to the documentation of the IRIS-Net™ software.

Installation Notes

1.Switch the power amp’s power off and pull the mains plug

2.Remove the cover panel from the rear panel (4 screws)

3.Insert the RCM-26 module in the slot and lock it in place on the rear panel using the 4 screws (see illustration 4.1)

Illustration 4.1: Installation of a RCM-26

4.Set the module’s CAN-address using the ADDRESS selector switches

5.Connect the needed interfaces (CAN, Audio, Control Port, RS-232)

6.Reconnect the mains cord and switch on the power amplifier

7.The power amp automatically recognizes the installed RCM-26 module

IRIS-Net

Configuring and controlling a remote amplifier with a RCM-26 module installed is possible through the use of IRIS-Net™ (Intelligent Remote & Integrated Supervision) PC-software. IRIS-Net™ allows programming the RCM-26 module’s complete configuration while the computer is off-line. All instructions on how to configure, operate and monitor all RCM-26 functions are included in the IRIS-Net™ help files.

Illustration 4.2: DSP flow diagram of the RCM-26

36 Owner’s Manual

Page 36
Image 36
Dynacord H 2500, H 5000 owner manual Installation Notes, IRIS-Net