Dynacord H 2500, H 5000 owner manual H5000

Models: H 2500 H 5000

1 144
Download 144 pages 16.51 Kb
Page 136
Image 136

PowerH SERIES

H5000

Amplifier at rated conditions, both channels driven, 8 Ω loads, unless otherwise specified.

Load Impedance

2 Ω

 

4 Ω

 

8 Ω

Maximum Midband Output Power

3500 W

 

2500 W

 

1500 W

THD = 1%, 1 kHz, Dual Channel

 

 

 

 

 

 

 

Rated Output Power

-

 

2100 W

 

1050 W

THD < 0.1%, 20 Hz...20 kHz

 

 

 

 

 

 

 

Maximum Single Channel Output Power

4500 W

 

3200 W

 

1800 W

Dynamic-Headroom, IHF-A

 

 

 

 

 

 

 

Maximum Single Channel Output Power

4100 W

 

2700 W

 

1600 W

Continuous, 1 kHz

 

 

 

 

 

 

 

Maximum Bridged Output Power

-

 

7000 W

 

5000 W

THD = 1%, 1 kHz

 

 

 

 

 

 

 

Maximum RMS Voltage Swing

 

 

125 V

 

THD = 1%, 1 kHz

 

 

 

 

 

 

 

 

Power Bandwidth

 

 

10 Hz...50 kHz

 

THD = 1%, ref. 1 kHz, half power @ 4 Ω

 

 

 

 

 

 

 

 

Voltage Gain, ref. 1 kHz

 

41 dB / 35 dB / 32 dB (switchable)

 

Input Sensitivity

 

0 dBu / +6 dBu / +9 dBu (switchable)

 

rated power @ 8 Ω, 1 kHz

 

 

 

 

 

 

 

THD at rated output power

 

< 0.05%

 

 

MBW = 80 kHz, 1 kHz

 

 

 

 

 

 

 

 

IMD-SMPTE

 

< 0.05%

 

 

60 Hz, 7 kHz

 

 

 

 

 

 

 

 

DIM30

 

< 0.02%

 

 

3.15 kHz, 15 kHz

 

 

 

 

 

 

 

 

Maximum Input Level

 

 

+22 dBu (9.75 Vrms)

 

Crosstalk

 

 

< -80 dB

 

ref. 1 kHz, at rated output power

 

 

 

 

 

 

 

 

Frequency Response ref. 1 kHz

 

< 10 Hz...30 kHz (±1 dB)

 

Input Impedance active balanced

 

 

20 kΩ

 

Damping Factor 1 kHz

 

> 400

 

 

Slew Rate

 

 

35 V/μs

 

Signal to Noise Ratio Amplifier

 

 

111 dB

 

A-weighted, 32 dB constant gain

 

 

 

 

 

 

 

 

Output Noise, A-weighted

 

 

< -70 dBu

 

Output Stage Topology

 

Class H Grounded Bridge (3-stage)

 

Power Requirements

 

100-240 V, 50-60 Hz / 100 V, 50-60 Hz

 

Power Consumption

 

 

1450 W

 

1/8 maximum output power @ 4 Ω

 

 

 

 

 

 

 

 

Protection

Audio Limiters, High Temperature, DC, HF, Short Circuit, Back-EMF,

 

Peak Current Limiters, Inrush Current Limiters, Turn-on Delay, Mains

 

Circuit Breaker Protection, Mains Overvoltage Protection

Cooling

 

Front-to-Rear, 5-Stage-Fans

 

Ambient Temperatur Limits

 

+5 °C...+40 °C (40 °F...105 °F)

 

Safety Class

 

 

I

 

Dimensions (W x H x D), mm

 

 

483 x 88.1 x 497.5

 

Weight

 

 

14.5 kg (32.0 lbs)

 

Depending on the ambient temperature, the unit might not operate continuously at 2 Ω load in Normal Mode or 4 Ω in Bridged Mode.