PowerH SERIES

During installation, always separate the power amplifier from the mains. Connect the power amplifier only to a mains network, which corresponds to the requirements indicated on the type plate.

Illustration 2.3: H2500/H5000 type plate

Device

Voltage

Frequency

Power Consumption

 

 

 

 

H2500

100-240 V

50-60 Hz

1000 W

 

 

 

 

H5000

100-240 V

50-60 Hz

1450 W

 

 

 

 

 

Table 2.4: Specifications for the Power Supply Unit

Mains Operation & Resulting Temperature

The following tables allow the determination of power supply and cabling requirements. The power drawn from the mains network is converted into output power to feed the connected loudspeaker systems and into heat. The difference between power consumption and dispensed power is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the ventilation efforts necessary.

The column Pd lists the leakage power in relation to different operational states. The column BTU/hr lists the dispensed heat amount per hour.

H2500

Umains in V

Imains in A

Pmains in W

Pout in W

Pd in W1

BTU/hr2

Idle

230

0.7

70

-

70

239

Max. Output Power @ 8 Ω3

230

15.3

2420

2 x 850

720

2457

Max. Output Power @ 4 Ω3

230

25.7

4300

2 x 1450

1400

4777

1/3 Max. Output Power @ 4 Ω3

230

14.7

2325

2 x 483

1358

4635

1/8 Max. Output Power @ 4 Ω3

230

6.2

875

2 x 181

513

1749

1/8 Max. Output Power @ 4 Ω4

230

6.7

1000

2 x 181

588

2005

1/8 Max. Output Power @ 4 Ω4 5

253

7.1

1105

2 x 219

666

2274

Normal Mode (-10 dB) @ 4 Ω3

230

5.6

775

2 x 145

485

1655

Rated Output Power (0 dB) @ 4 Ω3

230

23.5

3900

2 x 1200

1500

5118

Alert (Alarm) Mode (-3 dB) @ 4 Ω3

230

16.7

2665

2 x 600

1465

4999

Max. Output Power @ 2 Ω3

230

39.6

6920

2 x 2000

2920

9963

1/8 Max. Output Power @ 2 Ω3

230

9.1

1345

2 x 238

870

2969

1/8 Max. Output Power @ 2 Ω4

230

9.1

1335

2 x 238

860

2934

10 Owner’s Manual

Page 10
Image 10
Dynacord H 2500, H 5000 owner manual Mains Operation & Resulting Temperature, H2500