During installation, always separate the power amplifier from the mains. Connect the power amplifier only to a mains network, which corresponds to the requirements indicated on the type plate.
Illustration 2.3: H2500/H5000 type plate
Device | Voltage | Frequency | Power Consumption |
|
|
|
|
H2500 | 1000 W | ||
|
|
|
|
H5000 | 1450 W | ||
|
|
|
|
| Table 2.4: Specifications for the Power Supply Unit |
Mains Operation & Resulting Temperature
The following tables allow the determination of power supply and cabling requirements. The power drawn from the mains network is converted into output power to feed the connected loudspeaker systems and into heat. The difference between power consumption and dispensed power is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a
The column Pd lists the leakage power in relation to different operational states. The column BTU/hr lists the dispensed heat amount per hour.
H2500 | Umains in V | Imains in A | Pmains in W | Pout in W | Pd in W1 | BTU/hr2 |
Idle | 230 | 0.7 | 70 | - | 70 | 239 |
Max. Output Power @ 8 Ω3 | 230 | 15.3 | 2420 | 2 x 850 | 720 | 2457 |
Max. Output Power @ 4 Ω3 | 230 | 25.7 | 4300 | 2 x 1450 | 1400 | 4777 |
1/3 Max. Output Power @ 4 Ω3 | 230 | 14.7 | 2325 | 2 x 483 | 1358 | 4635 |
1/8 Max. Output Power @ 4 Ω3 | 230 | 6.2 | 875 | 2 x 181 | 513 | 1749 |
1/8 Max. Output Power @ 4 Ω4 | 230 | 6.7 | 1000 | 2 x 181 | 588 | 2005 |
1/8 Max. Output Power @ 4 Ω4 5 | 253 | 7.1 | 1105 | 2 x 219 | 666 | 2274 |
Normal Mode | 230 | 5.6 | 775 | 2 x 145 | 485 | 1655 |
Rated Output Power (0 dB) @ 4 Ω3 | 230 | 23.5 | 3900 | 2 x 1200 | 1500 | 5118 |
Alert (Alarm) Mode | 230 | 16.7 | 2665 | 2 x 600 | 1465 | 4999 |
Max. Output Power @ 2 Ω3 | 230 | 39.6 | 6920 | 2 x 2000 | 2920 | 9963 |
1/8 Max. Output Power @ 2 Ω3 | 230 | 9.1 | 1345 | 2 x 238 | 870 | 2969 |
1/8 Max. Output Power @ 2 Ω4 | 230 | 9.1 | 1335 | 2 x 238 | 860 | 2934 |