RTM-ATCA-SXXX Overview

the clear password procedure is explained in section 9.4.3 of this manual. When invoked, the user is prompted to set a new one at first login.

Note: The recovery procedure affects the “root” user only; No other user account passwords are cleared.

3.3Factory reset

Users can reset the blade to restore factory default settings. This procedure will erase all existing blade configurations (network settings, volumes, shares etc). The procedure is sometimes recommended following a major firmware upgrade.

i.Login into shell window as root

ii.At console prompt, type: fw_setenv setfactorydefaults 1

3.4Configuring a new ATCA-S201 blade

Initial configuration and setup of your blade may be conducted over Ethernet or serial (RS232) connections. Select the connection type that supports your preferred management style, either CLI (command line tool) or HTML as outlined below:

Connection type

Command line tool

 

 

Serial/RS232 port on RTM

Yes

 

 

Ethernet port on RTM

Yes

 

 

Base or fabric ports on ATCA

Yes

Zone-2 connector

 

Secure html tool

Yes

Yes

3.4.1Serial ports

An RJ45 serial port can be found on RTM panel. The default baud rate and communication settings are listed in Table 5 Console port, default terminal settings in section 3.1.2. The serial port attributes such as baud rate may be changed in the U-boot environment using the bootargs variable (see section 3.6.3 titled U-boot environment variables).

3.4.2Ethernet ports

An RJ45 Ethernet port can be found on RTM panel. It auto negotiates Ethernet link speed s up to 1Gbps. Additional Ethernet ports (base and fabric) are provided on the ATCA zone-2 connector. By default, all Ethernet ports will attempt to obtain an IP address assignment form the DHCP (Dynamic Host Configuration Protocol) server on the network. Administrators must log into your DHCP server to determine the IP assignment. With the IP address, an administrator may connect to the ATCA-S201 using a secure shell (SSH) or an HTML browser which supports secure http connections. The Ethernet equipment can be identified by finding the IP address(es) corresponding to the following MAC address assignments:

MAC address OUI

00-11-0D-xx-xx-xx (hex)