RTM-ATCA-SXXX Overview

Note: The ‘share’ in this example is not yet visible externally via IP links, and external hosts cannot yet access this resource. Administrator should proceed to chapter 8 to create NFS or SMB mount points.

Upon completing these steps, the Mange share menu will update as shown below. Changes may be applied by clicking the appropriate box and clicking ‘Update’.

CLI command syntax

Table 31 CLI command syntax, format a logical volume

Convention:

<+skip>

Syntax example #1 Syntax example #2

atca_blade set_shares Y <diskmask> Y Y +

Use to ‘Y’ designate which disk to format. Use skip in all other positions. atca_blade set_shares Y skip Y Y Y +

Designate disk ‘lva’ an iSCSI share called iSCSI_target_AA

atca_blade set_shares Y N Y N Y iSCSI_targetBB Y Y +

Designate disk 2 of 2, an iSCSI share called iSCSI_target_BB

6.5.3Un-commit an iSCSI share

The administrator may modify or un-share any currently shared logical device by navigating to the html configuration screen:

Emerson ATCA-S201 Shares Manage Shares

The Manage shares menu displays the active status of all logical devices. Scroll to the device of interest, and complete the steps below.

Emerson ATCA-S201

+ iSCSI

+ nfs

+ smb

Shares

+Manage Shares

+MD RAIDLVM2

+ Hardware RAID

+ Physical Disks

+ Maintenance

6806800H62B ATCA‐S201 Installation and Use Guide

77

Page 87
Image 87
Emerson manual Un-commit an iSCSI share, Emerson ATCA-S201  Shares  Manage Shares