RTM-ATCA-SXXX Overview

J30- ATCA

e d c b a

1 2

Figure 35 ‘J30’ RTM Power Receptacle

10.2.4.4Connector J30, RTM Power Pin Assignment

The ATCA-S201 J30 connector pin assignments and descriptions appear below.

Table 53 J30, RTM Power Pin Header Assignment

 

 

 

 

 

Row#

Interface

1

2

a

Pwr

Logic_GND

Shelf_GND

b

Pwr

Logic_GND

+3.3V MP

c

IPMI

IPMI_SCL_L

IPMI_SDA_L

d

Pwr

+12V PP

+12V PP

e

Pwr

PS1#

NC

 

 

 

 

Table 54 Connector J30, RTM Power Pin Signal Descriptions

PS1#

IPMI_SCL_L

IPMI_SDA_L

12VPP

3.3V_MP

Shelf_GND Logic_GND

Active low RTM present signal. PS1# shall be pulled up to 3.3 V management power on the ATCA blade. PS0# (Connector P33) and PS1# (Connector P30) shall be connected through a diode on the ATCA-S201, exactly as defined in AMC.0 specification. PS1# is last mate on Power connector and PS0# is on the opposite end of the set of connectors. Logic low on PS1# indicates that RTM is present and fully inserted.

IPMI bus clock signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0specification.

IPMI bus data signal, as defined in AMC.0 specification. The RTM shall have a pull-up resistor for this signal as indicated in AMC.0 specification.

12 V payload power, enabled after successful E-keying, as outlined in the AMC.0 specification. RTM must meet requirements posted for payload power in AMC specification.

3.3V Management Power. RTM must meet requirements posted for management power in AMC.0 specification.

Frame/Chassis Safety Ground

(Logic 0vdc). Logic Ground- Common return for Management Power Payload Power, reference potential for single ended logic signaling, and shielding for differential pair signals in the AMC Connector.