J30

 

DDR2 DIMM

AMC slot B1

 

 

J32

 

CPU

 

J33

AMC slot B2

PCIe

 

Switch

 

SAS

AMC slot B3

10GbE

 

 

XAUI

 

J23

AMC slot B4

 

 

J10

ATCA-S201

 

Figure 30 ATCA-S201 Jumper locations

RTM-ATCA-SXXX Overview

JP1 3 2 1

JP2 3 2 1

9.4.2Emergency flash recovery (factory reset)

The method described in this section explains a procedure to repair primary flash contents that are blank, erased or corrupted. We advise against using this emergency recovery procedure if the ATCA-S201 is functional, and management communications can be conducted.

Upgrade firmware procedure

1.Remove the ATCA carrier the chassis (see 2.9, Removing the ATCA carrier blade)

2.Locate header JP1, and move the jumper to the service setting. This causes the blade to fetch firmware from the read-only factory flash.

3.Re-install the ATCA blade into the chassis and allow it to reboot.

6806800H62B ATCA‐S201 Installation and Use Guide