ATCA‐S201 Installation

2.10.1To Verify the Hardware Installation

1.After power is applied to the system, wait approximately 45 seconds for firmware to initialize the board.

2.Inspect the LEDs on the front of the ATCA panel. When properly installed and powered, the LEDs will illuminate as follows:

ATCA Hot Swap LED

Off: Normal, default state

ATCA Health status

Green-blinking: Healthy, OK

ATCA Out of service (OOS)

Off: Normal, default state

3.(Optional). There are five Ethernet ports on the ATCA blade:

1 management (on RTM)

2 ATCA base ports (zone-2 connector)

2 ATCA fabric ports (zone-2 connector)

If DHCP is running on the network, it is possible to immediately ping the Ethernet ports on the ATCA module. Open a command line window on any node, and attempt to ping the ATCA blade.

ok ping 192.168.1.xxx

Note1: Ping requires that you determine the IP address assigned to the blade. The carrier blades MAC address assignments are registered with the IANA public section of the IEEE Standards OUI (Organizational unique identifier) database. The Ethernet ports for the blade can be identified by finding the IP address corresponding to the following MAC address assignments:

MAC address OUI

00-11-0D-xx-xx-xx (hex)

6806800H62B ATCA‐S201 Installation and Use Guide

19

Page 29
Image 29
Emerson ATCA-S201 manual To Verify the Hardware Installation