Epson TM-T85P manual Control Commands, 2Commands

Models: TM-T85 TM-T85P

1 115
Download 115 pages 23.45 Kb
Page 60
Image 60

Control Commands

HT

[Name]

Horizontal tab

[Format]

ASCII

HT

 

Hex

09

 

Decimal

9

[Description]

Moves the print position to the next horizontal tab position.

[Notes]

• This command is ignored unless the next horizontal tab position

 

has been set.

 

• If the next horizontal tab position exceeds the printing area, the

 

printer sets the printing position to [Printing area width + 1].

 

• Horizontal tab positions are set with ESC D.

 

• If this command is received when the printing position is at

 

[printing area width + 1], the printer executes print buffer-full

 

printing of the current line and horizontal tab processing from the

 

beginning of the next line.

[Reference]

ESC D

 

LF

[Name]

Print and line feed

[Format]

ASCII

LF

 

Hex

0A

 

Decimal

10

[Description]

Prints the data in the print buffer and feeds one line based on the

 

current line spacing.

[Note]

This command sets the print position to the beginning of the line.

[Reference]

ESC 2, ESC 3

FF

[Name]

Print and return to standard mode (in page mode)

[Format]

ASCII

FF

 

Hex

0C

 

Decimal

12

[Description]

Prints the data in the print buffer collectively and returns to standard

 

mode.

 

[Notes]

• The buffer data is deleted after being printed.

 

• The printing area set by ESC W is reset to the default setting.

 

• The printer does not execute paper cutting.

 

• This command sets the print position to the beginning of the line.

 

• This command is enabled only in page mode.

[Reference] ESC FF, ESC L, ESC S