Freescale Semiconductor, Inc.

Freescale Semiconductor, Inc...

Chapter 3

Fast Ethernet Controller Operation

30

30

This chapter discusses the operation of the FEC.

3.1 Transceiver Connection

The FEC supports both an MII interface for 10/100 Mbps Ethernet and a seven-wire serial interface for 10-Mbps Ethernet. The interface mode is selected by R_CNTRL[MII_MODE], described in Section 6.2.20, ÒReceive Control Register (R_CNTRL).Ó Table 3-1 shows the 18 MII interface signals that are deÞned by the 802.3 standard.

Table 3-1. MII Signals

Signal Description

FEC Signal Name

 

 

Transmit clock

TX_CLK

 

 

Transmit enable

TX_EN

 

 

Transmit data

TXD[3:0]

 

 

Transmit error

TX_ER

 

 

Collision

COL

 

 

Carrier sense

CRS

 

 

Receive clock

RX_CLK

 

 

Receive enable

RX_DV

 

 

Receive data

RXD[3:0]

 

 

Receive error

RX_ER

 

 

Management channel clock

MDC

 

 

Management channel serial data

MDIO

 

 

Serial-mode connections to the external transceiver are shown in Table 3-2.

MOTOROLAChapter 3. Fast Ethernet Controller Operation3-1

PRELIMINARYÑSUBJECTFor ore nformationTO CHANGEOn ThisWITHOUTProduct,NOTICE

Go to: www.freescale.com

Page 21
Image 21