Important notes
Before starting up
VCAUTION!
●During installation and before operating the device, observe the instructions on environmental conditions for your device (see "Ambient conditions" on page 22).
●If the server has been moved from a cold environment, condensation may form both inside and on the outside of the machine.
Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server if this requirement is not met.
●Only transport the server in the original packaging or in packaging that protects it from impacts and jolts.
For the Japanese market, transporting the device in its original packaging does not apply.
Installation and operation
VCAUTION!
●The device may only be operated in a maximum ambient temperature of 35 °C.
●If the device is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the
●The device automatically adjusts to a mains voltage in the range of 100 - 240 V. Make sure that the local mains voltage is neither above nor below these limits.
●This device must only be connected to properly grounded power outlets or to the insulated sockets of the rack's internal power supply using
●Make sure that the device is connected to a protective contact socket that is close by the device.
26 | Operating Manual | BX400 S1 |