Setting plot interval 1 by time

The default plot method for plot interval 1 is time. To set plot interval

1 by time do the following:

1.Press the [MENU] key.

2.Press the [8] key to select INITIAL SETTINGS.

3.Select the PLOT INTERVAL 1 field.

8 INITIAL SETTINGS

INTERNAL NAV

=

 

 

ON

 

OFF

 

 

EXTERNAL NAV

= GPS

 

LC LA DC DR OFF

 

 

 

 

 

 

 

 

 

I/O DATA FORMAT

= CIF

NMEA183

 

NMEA180/182

SMOOTHING

= 00 (0-15)

 

 

 

 

 

 

 

 

 

PLOT INTERVAL 1

=

 

TIME

(00M10S)

DIST (0.10NM)

 

 

 

 

 

 

 

 

 

 

 

PLOT INTERVAL 2

= TIME (00M10S)

DIST

(0.10NM)

 

 

 

 

 

 

 

 

 

 

 

WAYPOINT MARK

 

=

 

ON

 

 

OFF

 

 

Figure 2-11 INITIAL SETTINGS menu

4.Enter a plot interval. To enter 30 seconds, for example, press [0], [0], [3] and [0].

5.Press the [ENT] key.

Setting plot interval 2 to “time”

The default plot method for PLOT INTERVAL 2 is distance. How- ever, it may be set for time as follows:

1.Press the [MENU] key.

2.Press the [8] key to select INITIAL SETTINGS.

3.Select the PLOT INTERVAL 2 field.

4.Select TIME.

5.Enter a plot interval. To enter 15 minutes, for example, press [1], [5], [0], [0].

6.Press the [ENT] key.

2-7

Page 38
Image 38
Furuno GP-3300, GD-3300 manual Setting plot interval 1 by time, Setting plot interval 2 to time