Greenheck Fan 470656 manual Reference - Model IG Venting Connection Location, Airflow

Models: 470656

1 72
Download 72 pages 41.99 Kb
Page 62
Image 62
Reference - Model IG Venting Connection Location

Reference - Model IG Venting Connection Location

Exhaust Outlet

Combustion Air Inlet

F

E

D

A

B

C

Discharge End

3/4-inch Gas Connection

Venting Location Dimensions

IG

A

B

C

D

E

G

Housing

 

 

 

 

 

 

 

 

 

 

 

 

 

10

3.89

5.12

9.12

11.59

23.11

27.58

20

3.91

3.89

7.89

11.62

25.34

32.27

30

3.91

3.89

7.89

11.62

25.34

32.27

Dimensions are in inches.

Dimensions B and E are not needed for standard venting. A round adapter should be used for the exhaust connection.

Flue Connection Size (diameter in inches)

IG

Standard

Non-Concentric

Concentric

Housing

Exhaust

Exhaust

Intake

Exhaust

Intake

10

4.0

4.0

4.0

4.0

6.0

20

6.0

6.0

6.0

6.0

8.0

30

6.0

6.0

6.0

6.0

8.0

Reference - Model IGX Venting Connection Location

Airflow

Exhaust Air Outlet

Combustion Air Intake

D

C

A

B

IGX

Furnace Size

 

 

 

 

 

Flue Connection Size (diameter in inches)

 

 

A

B

C

D

Standard

 

Non-Concentric

Concentric

 

Housing

(MBH)

 

 

 

 

 

 

Exhaust

 

Exhaust

Intake

Exhaust

 

Intake

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4.45

8.45

23.43

27.90

4.0

 

4.0

4.0

4.0

 

6.0

 

12

150

4.45

8.45

23.43

27.90

4.0

 

4.0

4.0

4.0

 

6.0

 

200

5.64

9.64

23.97

30.90

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

 

 

 

 

 

250

5.64

9.64

23.97

30.90

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

150

4.45

8.45

29.38

33.85

4.0

 

4.0

4.0

4.0

 

6.0

 

 

 

200

5.67

9.67

24.97

31.90

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

250

5.67

9.67

24.97

31.90

6.0

 

6.0

6.0

6.0

 

8.0

 

22

300

5.67

9.67

24.97

31.90

6.0

 

6.0

6.0

6.0

 

8.0

 

350

5.67

9.67

19.01

25.94

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

 

 

 

 

 

400

5.67

9.67

19.01

25.94

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

500

5.67

9.67

24.97

31.90

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

600

5.67

9.67

24.97

31.90

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

350

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

400

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

500

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

32

600

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

700

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

 

 

 

 

 

800

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

1050

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

 

 

1200

5.96

9.71

28.31

35.24

6.0

 

6.0

6.0

6.0

 

8.0

 

Dimensions are in inches. Dimensions A and C are not needed for standard venting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

Model IG / IGX Make-Up Air

 

 

 

 

 

 

 

 

 

®

Page 62
Image 62
Greenheck Fan 470656 Reference - Model IG Venting Connection Location, Reference - Model IGX Venting Connection Location