1–5

L100 Inverter

L100 Inverter Specifications

Model-specific tables for 200V and 400V class inverters

The following tables are specific to L100 inverters for the 200V and 400V class model groups. Note that “General Specifications” on page 1–9 apply to both voltage class groups. Footnotes for all specifications tables follow the table below.

Item

 

 

 

200V Class Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L100 inverters,

CE version

 

002NFE

 

004NFE

 

005NFE

 

007NFE

 

011NFE

200V models

 

 

 

 

 

 

 

 

 

 

 

 

UL version

 

002NFU

 

004NFU

 

 

007NFU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applicable motor size *2

 

kW

0.2

 

0.4

 

0.55

 

0.75

 

1.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

1/4

 

1/2

 

3/4

 

1

 

1 1/2

 

 

 

 

 

 

 

 

 

 

 

 

Rated capacity (240V) kVA *10

 

0.5

 

1.0

 

1.2

 

1.6

 

2.0

 

 

 

 

 

 

 

Rated input voltage

 

1-phase: 200 to 240V +5/-10%, 50/60 Hz ±5%,

 

 

 

 

3-phase: 200 to 240V +5/-10%, 50/60 Hz ±5%,

 

 

 

 

 

(037LFU, 055LFU & 075LFU 3-phase only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated input

1-phase

 

3.1

 

5.8

 

6.7

 

9.0

 

11.2

current (A)

 

 

 

 

 

 

 

 

 

 

 

 

3-phase

 

1.8

 

3.4

 

3.9

 

5.2

 

6.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated output voltage *3

 

3-phase: 200 to 240V (corresponding to input voltage)

 

 

 

 

 

 

 

 

 

 

Rated output current (A)

 

1.4

 

2.6

 

3.0

 

4.0

 

5.0

 

 

 

 

 

 

 

 

 

 

Efficiency at 100% rated output (%)

91.5

 

92.8

 

93.6

 

94.1

 

95.4

 

 

 

 

 

 

 

 

 

 

 

 

Watt loss,

at 70% output

13

 

21

 

25

 

31

 

38

approximate (W)

 

 

 

 

 

 

 

 

 

 

at 100% output

17

 

29

 

32

 

41

 

51

 

 

 

 

 

 

 

 

 

 

 

 

Braking

Dynamic

 

 

 

 

100%: 50 Hz,

 

 

 

 

braking, approx.

 

 

 

50%: 60 Hz

 

 

 

 

% torque, (short

 

 

 

 

 

 

 

 

 

 

Capacitive feedback type, dynamic braking unit and braking

 

time stop from

 

 

 

resistor optional, individually installed

 

 

50 / 60 Hz) *5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC braking

 

Variable operating frequency, time, and braking force

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

kg

0.85

 

0.85

 

1.3

 

1.3

 

2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lb

1.87

 

1.87

 

2.87

 

2.87

 

4.85

 

 

 

 

 

 

 

 

 

 

 

 

 