L100 Inverter
Terminal Dimensions and Torque SpecsThe terminal screw dimensions for all L100 inverters are listed in table below. This information is useful in sizing spade lug or ring lug connectors for wire terminations.
CAUTION: Fasten the screws with the specified fastening torque in the table below. Check for any loosening of screws. Otherwise, there is the danger of fire.
|
|
|
|
| Models | Models 005NF– |
| Models |
|
| ||||||
|
|
| Number |
| 022NF, 037LF, |
|
|
| ||||||||
|
|
|
| 002NF, 004NF |
|
|
| |||||||||
|
|
|
|
|
| MountingInverter Installationand | ||||||||||
| Connector | of Screw |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Terminals |
| Screw | Width | Screw |
| Width |
| Screw |
| Width |
|
| |
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| Diameter | (mm) | Diameter |
| (mm) |
| Diameter |
| (mm) |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power Terminals | 12 |
| M3.5 | 7.1 | M4 | 9 |
| M5 |
| 13 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Control Signal | 15 |
| M2 | — | M2 |
| — |
| M2 |
| — |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Alarm Signal | 3 |
| M3 | — | M3 |
| — |
| M3 |
| — |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ground Terminals | 2 |
| M4 | — | M4 |
| — |
| M4 |
| — |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| When connecting wiring, use the tightening torque listed in the following table to safely |
| |||||||||||||
|
| attach wiring to the connectors. |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||||||
| Screw | Tightening Torque | Screw |
| Tightening Torque |
| Screw |
| Tightening Torque |
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
| M2 | 0.2 N•m (max. 0.25 N•m) | M3.5 |
| 0.8 N•m (max. 0.9 N•m) |
| M5 | 2.0 N•m (max. 2.2 N•m) |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| M3 | 0.5 N•m (max. 0.6 N•m) | M4 |
| 1.2 N•m (max. 1.3 N•m) |
| — |
| — |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Step 6: In this step, you will connect wiring to
6the input of the inverter. First, you must deter- mine whether the inverter model you have requires
The wiring example to the right shows an L100 inverter wired for