Item | 400V Class Specifications, continued |
|
|
L100 inverters, | CE version |
| 030HFE |
| 040HFE | 055HFE |
| 075HFE | Getting | |
|
|
|
| |||||||
400V models |
|
|
|
|
|
|
|
|
|
|
UL version |
| — |
| 040HFU | 055HFU |
| 075HFU |
| ||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
Applicable motor size *2 |
| kW | 3.0 |
| 4.0 | 5.5 |
| 7.5 | Started | |
|
|
|
|
|
|
|
|
|
| |
|
|
| HP | 4 |
| 5 | 7.5 |
| 10 | |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |
Rated capacity (460V) kVA *10 |
| 6.2 |
| 6.8 | 10.4 |
| 12.7 |
| ||
|
|
|
|
|
|
| ||||
Rated input voltage |
|
| ||||||||
|
|
|
|
|
|
|
| |||
Rated input current (A) |
| 10.0 |
| 11.0 | 16.5 |
| 20.0 |
| ||
|
|
|
|
|
|
| ||||
Rated output voltage *3 |
|
| ||||||||
|
|
|
|
|
|
|
| |||
Rated output current (A) |
| 7.8 |
| 8.6 | 13 |
| 16 |
| ||
|
|
|
|
|
|
|
| |||
Efficiency at 100% rated output (%) | 95.4 |
| 96.2 | 96.0 |
| 96.5 |
| |||
|
|
|
|
|
|
|
|
|
| |
Watt loss, | at 70% output | 100 |
| 108 | 156 |
| 186 |
| ||
approximate (W) |
|
|
|
|
|
|
|
| ||
at 100% output | 138 |
| 151 | 219 |
| 261 |
| |||
|
|
|
|
|
|
|
| |||
Braking | Dynamic |
| 40%: ≤ 50Hz, | 20%: ≤ 50Hz |
| |||||
| braking, approx. | 20%: ≤ 60Hz | 20%: ≤ 60Hz |
| ||||||
| % torque, (short |
|
|
|
|
|
|
| ||
| Capacitive feedback type, dynamic braking unit and braking |
| ||||||||
| time stop from |
| ||||||||
|
| resistor optional, individually installed |
|
| ||||||
| 50 / 60 Hz) *5 |
|
|
| ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
| ||||||
| DC braking |
| Variable operating frequency, time, and braking force |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
Weight |
|
| kg | 2.8 |
| 2.8 | 5.5 |
| 5.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| lb | 6.17 |
| 6.17 | 12.13 |
| 12.57 |
|
|
|
|
|
|
|
|
|
|
|
|
The following table applies to all L100 inverters.
Item | General Specifications |
|
|
|
|
Protective housing *1 | IP20 |
|
|
Control method | Sine wave |
|
|
Output frequency range *4 | 0.5 to 360 Hz |
|
|
Frequency accuracy | Digital command: 0.01% of the maximum frequency |
| Analog command: 0.1% of the maximum frequency (25°C ± 10°C) |
|
|
Frequency setting resolution | Digital: 0.1 Hz; Analog: max. frequency/1000 |
|
|
Volt./Freq. characteristic | V/f optionally variable, V/f control (constant torque, reduced torque) |
|
|
Overload current rating | 150%, 60 seconds |
|
|
Acceleration/deceleration time | 0.1 to 3000 sec., (linear accel/decel), second accel/decel setting |
| available |
|
|