L100 Inverter Specifications
Item | General Specifications |
|
|
Started |
| Input | Freq. |
| Operator panel | Up and Down keys / Value settings |
|
|
| ||||
|
| signal | setting |
|
|
|
|
|
| Potentiometer | Analog setting | ||
|
|
|
|
| ||
|
|
|
|
|
|
|
Getting |
|
| REV |
| External signal | 0 to 10 VDC (input impedance 10k Ohms), 4 to 20 mA (input |
|
|
| *6 | impedance 250 Ohms), Potentiometer (1k to 2k Ohms, 2W) | ||
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| FWD/ |
| Operator panel | Run/Stop (Forward/Reverse run change by command) |
|
|
|
|
|
|
|
|
|
| Run |
| External signal | Forward run/stop, Reverse run/stop |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
| Intelligent input | FW (forward run command), RV (reverse run command), CF1~CF4 | ||
|
|
| ||||
|
|
| terminal |
| ||
|
|
|
|
|
| decel. command), FRS (free run stop command), EXT (external |
|
|
|
|
|
| trip), USP (startup function), SFT (soft lock), AT (analog current |
|
|
|
|
|
| input select signal), RS (reset), PTC (thermal protection) |
|
|
|
|
| ||
|
| Output | Intelligent output | RUN (run status signal), FA1,2 (frequency arrival signal), OL | ||
|
| signal | terminal |
| (overload advance notice signal), OD (PID error deviation signal), | |
|
|
|
|
|
| AL (alarm signal) |
|
|
|
|
| ||
|
|
| Frequency monitor | PWM output; Select analog output frequency monitor, analog output | ||
|
|
|
|
|
| current monitor or digital output frequency monitor |
|
|
|
|
|
| |
|
| Alarm output contact | ON for inverter alarm (1C contacts, both normally open or closed | |||
|
|
|
|
|
| avail.) |
|
|
|
|
| ||
|
| Other functions |
| AVR function, curved accel/decel profile, upper and lower limiters, | ||
|
|
|
|
|
| |
|
|
|
|
|
| frequency change (0.5 to 16 kHz) frequency jump, gain and bias |
|
|
|
|
|
| setting, process jogging, electronic thermal level adjustment, retry |
|
|
|
|
|
| function, trip history monitor |
|
|
|
|
| ||
|
| Protective function |
| |||
|
|
|
|
|
| low temperature, CPU error, memory error, ground fault detection at |
|
|
|
|
|
| startup, internal communication error, electronic thermal |
|
|
|
|
|
| |
|
| Operat- | Temperature | Operating (ambient): | ||
|
| ing |
|
|
|
|
|
| Humidity | 20 to 90% humidity | |||
|
| Environ | ||||
|
|
|
|
|
| |
|
| ment | Vibration *9 | 5.9 m/s2 (0.6G), 10 to 55 Hz | ||
|
|
| Location |
| Altitude 1,000 m or less, indoors (no corrosive gasses or dust) | |
|
|
|
|
|
|
|
|
| Coating color |
| Light purple, cooling fins in base color of aluminum | ||
|
|
|
|
|
|
|
|
| Options |
|
|
| Remote operator unit, copy unit, cables for the units, dynamic |
|
|
|
|
|
| braking unit, braking resistor, AC reactor, DC reactor, noise filter, |
|
|
|
|
|
| DIN rail mounting |