L100 Inverter Specifications
Item | 400V Class Specifications |
|
|
Started |
| L100 inverters, | CE version |
| 004HFE |
| 007HFE | 015HFE | 022HFE | |
|
|
|
| |||||||
|
| 400V models |
|
|
|
|
|
|
|
|
|
| UL version |
| 004HFU |
| 007HFU | 015HFU | 022HFU | ||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
Getting |
| Applicable motor size *2 |
| kW | 0.4 |
| 0.75 | 1.5 | 2.2 | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| HP | 1/2 |
| 1 | 2 | 3 | |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |
|
| Rated capacity (460V) kVA *10 |
| 1.1 |
| 1.9 | 3.0 | 4.3 | ||
|
|
|
|
|
|
|
| |||
|
| Rated input voltage |
| |||||||
|
|
|
|
|
|
|
| |||
|
| Rated input current (A) |
| 2.0 |
| 3.3 | 5.0 | 7.0 | ||
|
| |||||||||
|
|
|
|
|
|
|
| |||
|
| Rated output voltage *3 |
| |||||||
|
|
|
|
|
|
|
| |||
|
| Rated output current (A) |
| 1.5 |
| 2.5 | 3.8 | 5.5 | ||
|
|
|
|
|
|
|
| |||
|
| Efficiency at 100% rated output (%) | 92.0 |
| 93.7 | 95.7 | 95.8 | |||
|
|
|
|
|
|
|
|
|
| |
|
| Watt loss, | at 70% output | 25 |
| 33 | 48 | 68 | ||
|
| approximate (W) |
|
|
|
|
|
| ||
|
| at 100% output | 32 |
| 44 | 65 | 92 | |||
|
|
|
|
|
|
|
|
|
| |
|
| Braking | Dynamic |
|
|
| 100%: ≤ 50Hz |
| 40%: ≤ 50Hz, | |
|
|
| braking, approx. |
|
| 50%: ≤ 60Hz |
| 20%: ≤ 60Hz | ||
|
|
| % torque, (short |
|
|
|
|
| ||
|
|
| Capacitive feedback type, dynamic braking unit and braking | |||||||
|
|
| time, stopping | |||||||
|
|
|
| resistor optional, individually installed | ||||||
|
|
| from 50 / 60 Hz) |
| ||||||
|
|
|
|
|
|
|
| |||
|
|
| *5 |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
| DC braking |
| Variable operating frequency, time, and braking force | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| Weight |
|
| kg | 1.3 |
| 1.7 | 1.7 | 2.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| lb | 2.87 |
| 3.75 | 3.75 | 6.17 |
|
|
|
|
|
|
|
|
|
|
|