Using the Front Panel Keypad
Inverter Mounting | and Installation |
|
|
In order to run the motor for the powerup test, this section will show how to:
•select the inverter’s maximum output frequency to the motor
•select the keypad potentiometer as the source of motor speed command
•select the keypad as the source of the RUN command
•enable the RUN command
The following series of programming tables are designed for successive use. Each table uses the previous table’s final state as the starting point. Therefore, start with the first and continue programming until the last one. If you get lost or concerned that some of the other parameters settings may be incorrect, refer to “Restoring Factory Default Settings” on page
CAUTION: If you operate a motor at a frequency higher than the inverter standard default setting (50Hz/60Hz), be sure to check the motor and machine specifications with the respective manufacturer. Only operate the motor at elevated frequencies after getting their approval. Otherwise, there is the danger of equipment damage.
Setting the Motor Base Frequency
|
| Action | Display | Func./Parameter | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Press the FUNC. key. |
|
| d | 0 1 | Monitor functions | ||
|
|
| |||||
|
|
|
|
|
|
|
|
Press the | 1 | or | 2 | keys until | d | 0 1 | “A” Group selected |
| |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Press the FUNC. key. |
|
| A | 0 1 | First “A” parameter | ||
|
|
| |||||
|
|
|
|
|
|
|
|
Press the | 1 | key twice. | A | 0 3 | Base frequency setting | ||
| |||||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Press the FUNC. key. |
|
| 6 0 | Default value for base frequency. | |||
|
| US = 60 Hz, Europe = 50 Hz. | |||||
|
|
|
|
|
| or |
|
|
|
|
|
|
| 5 0 |
|
|
|
|
|
|
|
|
|
Press the | 1 | or | 2 | key as needed. |
| 6 0 | Set to your motor specs (your |
| display may be different) | ||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Press the STR | key. |
| A | 0 3 | Stores parameter, returns to “A” | ||
| Group list | ||||||
|
|
|
|
|
|
|
|
TIP: If you need to scroll through a function or parameter list, press and hold the 1 or 2 key to