DCS 500 manual Mains overvoltage, Mains voltage 130% of nominal value for, longer than 10s, IV A 4

Models: 500

1 76
Download 76 pages 28.4 Kb
Page 59
Image 59
Mains overvoltage

Chapter 4 - Signals and Troubleshooting

Code

Text on

Definition /

Status

Remark

seven

LCD of control panel

Action

signal

 

segm.

CDP 31x

 

(FAULT_WORD_1/2)

 

display

 

 

 

 

 

 

F 28 Armature over-

Armature (DC circuit) overvoltage

11101 bit 2

(1)

voltage

Check: - Setting of param. [P 511] suitable

 

 

 

for the system configuration?

 

 

-Setting of field current and actual value as well as the complete field supply (FIELD EXCITER);

-Was the motor accelerated by the load?

-Speed scaling;

-Armature voltage feedback;

-Connections between SDCS- CON-x and SDCS-PIN boards;

-Coding of voltage evaluation on SDCS-PIN-xx board.

F 29 Mains undervoltage Mains supply undervoltage (AC); setting via

11101 bit 11

(3)

parameter [P 509]

 

 

Check: - Does the supply voltage exist?

 

 

-Did the mains contactor close?

-Setting of voltage feedback coding (voltage scaling) correct?

-Connections between SDCS- CON-x and SDCS-PIN-xx boards;

-Coding of voltage evaluation on SDCS-PIN-xx board.

F 30

Mains overvoltage

Mains supply overvoltage (AC)

11101

bit 12

(1)

 

 

Mains voltage > 130% of nominal value for

 

 

 

 

 

longer than 10s.

 

 

 

 

 

Fault tracing see Fault Code F 29.

 

 

 

 

 

 

 

 

 

F 31

Not in synchronism

Synchronization fault (of mains)

11101

bit 13

(3)

 

 

Check: - Mains supply, fuses etc.;

 

 

 

 

 

- Mains voltage and stability.

 

 

 

 

 

 

 

 

 

F 32

Field ex.1 overcurr

FIELD EXCITER 1 (field supply 1) overcurrent

11101

bit 14

(1)

 

 

Check: - Parameters of FIELD EXCITER 1;

 

 

 

-Connections of field exciter as well as insulation level of cable and of field winding.

F 33 Field ex.1 comerror

FIELD EXCITER 1 communication error

11101 bit 15

(1)

Check: - Flat cable connections X14: or cable X16: between SDCS- CON-x board and field exciter;

- Auxil. voltage for ext. field exciter.

DCS 500B / DCP 500B Operating Instructions

IV A 4 - 7

3ADW000055R0401_DCS500B_Operating Instruction_e_d