DCS 500 manual Reversal Fault, F 66 Current Difference, Signals and Troubleshooting, IV A 4

Models: 500

1 76
Download 76 pages 28.4 Kb
Page 63
Image 63
Reversal Fault

Chapter 4 - Signals and Troubleshooting

Code

Text on

Definition /

Status

Remark

seven

LCD of control panel

Action

signal

 

segm.

CDP 31x

 

(FAULT_WORD_1/2)

 

display

 

 

 

 

 

 

F 65

Reversal Fault

Reversal of direction of current is not O.K.

11103 bit 15

(3)

The reversal of the direction of current was not correct.

Check: - External cabling between both thyristor power converters;

-Correct plugging in of flat cable X18:?

F 66 Current Difference

Current feedback difference (deviation) be-

11103 bit 14

(3)

 

tween Master and Slave Drive

 

 

There is a current feedback difference (de- viation) between Master and Slave Drive (in twelve pulse configuration).

Check: - Parameter settings [P 3606] and [P 3605];

-Power-circuit cabling;

-Symmetry of control logic and scaling of signals exchanged between Master and Slave Drive.

DCS 500B / DCP 500B Operating Instructions

IV A 4 - 11

3ADW000055R0401_DCS500B_Operating Instruction_e_d

Page 63
Image 63
DCS Reversal Fault, F 66 Current Difference, Signals and Troubleshooting, DCS 500B / DCP 500B Operating Instructions