Chapter 4 - Signals and Troubleshooting

 

Code

 

 

Text on

 

 

Definition /

 

Status

 

 

Remark

 

seven

 

 

LCD of control panel

 

 

Action

 

signal

 

 

 

 

segm.

 

 

 

 

 

 

 

CDP 31x

 

 

 

 

(FAULT_WORD_1/2)

 

 

 

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 8

 

Current rise fault

 

Actual current changed faster than allowed

11103

bit 10

(2)

 

 

 

 

 

 

The rate of current change is monitored.

 

 

 

 

 

 

 

 

 

 

 

 

Check: - Setting of current reference slope

 

 

 

 

 

S21.232

 

 

 

 

 

 

 

[P406] and CURRENT_RISE_MAX

 

 

 

 

 

 

 

 

 

 

 

 

[P418];

 

 

 

 

 

and

 

 

 

 

 

 

 

 

 

 

 

 

higher

 

 

 

 

 

 

 

Level and setting of line voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and motor voltage; setting of

 

 

 

 

 

 

 

 

 

 

 

 

 

current controler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 14

 

Speed meas. fault

 

Speed feedback (measurement) fault

11102

bit 5

(3)

 

 

 

 

 

 

Check: - Incremental encoder and connec-

 

 

 

 

 

 

 

 

 

 

 

 

 

tion cable, encoder power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

(feedback might be too low);

 

 

 

 

 

 

 

 

 

 

 

 

 

- Tacho polarity and voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

(does a total mismatch exist?)

 

 

 

 

 

 

 

 

 

 

 

 

 

- Electronic boards SDCS-CON-x,

 

 

 

 

 

 

 

 

 

 

 

 

 

SDCS-IOB-3, SDCS-POW 1;

 

 

 

 

 

 

 

 

 

 

 

 

 

- Connection converter – armature

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit open?

 

 

 

 

 

 

 

 

 

 

 

 

 

- Correct setting for selection of

 

 

 

 

 

 

 

 

 

 

 

 

 

speed feedback monitoring?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 17

 

Type coding fault

 

(Converter) Type coding fault

11102

bit 8

(1)

 

 

 

 

 

 

SDCS-PIN-xx board not connected to board

 

 

 

 

 

Can

 

 

 

 

 

 

SDCS-CON-x or SDCS-PIN-xx not coded.

 

 

 

 

 

not be

 

 

 

 

 

 

Check: - Flat cables X12 and X13 O.K.?

 

 

 

 

 

reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Faulty coding on SDCS-PIN-xx?

 

 

 

 

 

 

 

 

 

 

 

 

 

- Correct coding of unit size C4?

 

 

 

 

 

 

 

 

 

 

 

 

Note: This fault signal will be shown, if jumper S2 (on board

 

 

 

 

 

 

 

 

 

 

 

 

SDCS-CON-x) is in position 1–2 while switching ON the elec-

 

 

 

 

 

 

 

 

 

 

 

 

tronics supply. In that case select BACKUP-STOREMODE

 

 

 

 

 

 

 

 

 

 

 

 

[11202], save the paramter set, switch OFF the electronics,

 

 

 

 

 

 

 

 

 

 

 

 

reset jumper S2 and switch ON the electronics again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 18

 

Backup read fault

 

Backup read fault (Parameter saving fault)

11102

bit 9

(1)

 

 

 

 

 

 

Cause: Wrong or missing checksum, data error

 

 

 

 

 

Can

 

 

 

 

 

 

while writing or reading.

 

 

 

 

 

not be

 

 

 

 

 

 

Note: Try again BACKUP-STORE-MODE; for that purpose

 

 

 

 

 

reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Move jumper S2 (on board SDCS-CON-x) to Pos. 1–2

 

 

 

 

 

 

 

 

 

 

 

 

 

with electronics supply switched OFF;

 

 

 

 

 

 

 

 

 

 

 

 

-

Switch ON electronics again;

 

 

 

 

 

 

 

 

 

 

 

 

- Select BACKUPSTOREMODE [11202];

 

 

 

 

 

 

 

 

 

 

 

 

-

Save default parameter set;

 

 

 

 

 

 

 

 

 

 

 

 

-

Switch OFF electronics;

 

 

 

 

 

 

 

 

 

 

 

 

-

Reset jumper S2 to ist original position;

 

 

 

 

 

 

 

 

 

 

 

 

-

Switch ON electronics again.

 

 

 

 

 

 

 

 

 

 

 

 

If display shows F 18 once again, change SDCS-CON-x

 

 

 

 

 

 

 

 

 

 

 

 

board!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCS 500B / DCP 500B Operating Instructions

IV A 4 - 5

3ADW000055R0401_DCS500B_Operating Instruction_e_d

Page 57
Image 57
DCS 500 manual P418, SDCS-IOB-3, SDCS-POW