DCS 500 manual 11203, Fexcstatus, Signals and Troubleshooting, 11202, IV A 4

Models: 500

1 76
Download 76 pages 28.4 Kb
Page 71
Image 71
11203

Chapter 4 - Signals and Troubleshooting

 

Para-

 

 

Code

 

 

Text on LCD of con-

 

 

Definition / explication of the signal

 

 

Remark

 

 

 

 

/

 

 

 

 

 

 

 

 

meter

 

 

 

 

trol panel CDP 31x

 

 

 

 

 

 

 

 

 

 

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

READ APPL BLOCKS

Load application; if additional function blocks are ac-

 

 

 

 

 

 

 

 

 

 

 

 

 

tivated and saved via SAVE MOTx SET and modified

 

 

 

 

 

 

 

 

 

 

 

 

 

afterwards without saving the configuration before

 

 

 

 

 

 

 

 

 

 

 

 

 

the last modification (the one directly after the last

 

 

 

 

 

 

 

 

 

 

 

 

 

SAVE action) can be activated

 

 

 

 

 

 

 

 

 

 

 

 

 

11202

--

----

 

While the command is executing the value of

 

 

 

 

 

 

 

 

 

 

 

 

 

BACKUPSTOREMODE will show what is happening

 

 

 

 

 

 

 

 

 

 

 

 

 

or the reason for error if the command fails

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

ERASE ERROR

Error during erasing of parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

ERASING…

Erasing the parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

PROGRAM ERROR

Error during programing of parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

PROGRAMMING…

Programing the parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

WRONG FLASH TYPE

Verification error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

READING…

Reading the parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

READ ERROR

Error during reading of parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

VERSION ERROR

Bad type of parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

SIZE ERROR

Bad size of parameter flash

 

 

 

 

 

 

 

 

 

 

 

 

 

11203

--

----

 

FEXC_STATUS:

 

 

 

 

 

 

 

 

 

 

 

 

 

Status of the field exciters 1 and 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

 

(FEXC1_RDY_OPER)

0

= not ready for operation; AC-voltage missing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

(FEXC1_OK)

0

= self diagnostic failed or power failure in FEX 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

 

(EXC2_RDY_OPER)

0

= not ready for operation; AC-voltage missing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03

 

(EXC2_OK)

0

= self diagnostic failed or power failure in FEX 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

 

(ACK_FEXC1_ON)

1

= motor 1 field OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05

 

(ACK_FEXC2_ON)

1

= motor 2 field OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

 

(FIELD_HEAT_ON)

1

= motor heating function active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

 

(FIELD1_REV_ACK

direction of the field 0 = forward, 1 = reverse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

 

(ACK_CSC_ON)

1

= on-command accepted by sequence control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

 

(ACK_FEXC_ON

1

= motor field OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

(FIELD_REF_ON)

1

= field current reference released

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

(FIELD1_CURR_MIN_L)

1

= motor 1 field current above min level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCS 500B / DCP 500B Operating Instructions

IV A 4 - 19

3ADW000055R0401_DCS500B_Operating Instruction_e_d

Page 71
Image 71
DCS manual 11203, Fexcstatus, Signals and Troubleshooting, 11202, DCS 500B / DCP 500B Operating Instructions, IV A 4