Chapter 4 - Signals and Troubleshooting

 

Code

 

 

Text on

 

 

 

Definition /

 

Status

 

Remark

 

seven

 

 

LCD of control panel

 

 

 

Action

 

signal

 

 

 

segm.

 

 

 

 

 

 

 

CDP 31x

 

 

 

 

 

 

(FAULT_WORD_1/2)

 

 

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 44

I/O-Board not found

 

 

Missing input/output (I/O-) boards

11101

bit 7

(1)

 

 

 

 

 

 

 

IOB1/2x/3/IOE1

 

 

 

 

 

 

Can

 

 

 

 

 

 

 

The existance of the boards had been recog-

 

 

 

 

not be

 

 

 

 

 

 

 

nized by the software and something hap-

 

 

 

 

reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pened to the board or the cable.

 

 

 

 

 

 

 

 

 

 

 

 

Check: - Is +/- 10 V supply available?

 

 

 

 

 

 

 

 

 

 

 

 

- Flat cable connections between

 

 

 

 

 

 

 

 

 

 

 

 

SDCS-CON-x and SDCS-IOB-1/2x/3/IOE1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 48

Motor 2 overtemp.

 

 

Overtemperature of MOTOR 2

11101

bit 8

(2)

 

 

 

 

 

 

 

Check: - Parameter setting MOT2 TEMP_

 

 

 

 

 

 

 

 

 

 

 

 

FAULT_L [P 1603] correct?

 

 

 

 

 

 

 

 

 

 

 

 

{See Fault Code F 6}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 50

No C FAN ack

 

 

No CONVERTER FAN supply acknowledge

11102

bit 10

(2)

 

 

 

 

 

 

 

Depending on type of unit (size):

 

 

 

 

 

 

 

 

 

 

 

 

Size C4

Fault signal F 50

 

 

 

 

 

 

 

 

 

 

 

 

Sizes C1/C2/A5

Alarm signal A 126

 

 

 

 

 

 

 

 

 

 

 

 

Check: - Was input for acknowledge

 

 

 

 

 

 

 

 

 

 

 

 

signal (parameter [P 910]) used?

 

 

 

 

 

 

 

 

 

 

 

 

{See Fault Code F 40}.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 52

No BRAKE ack

 

 

No BRAKE acknowledge

11101

bit 10

(2)

 

 

 

 

 

 

 

Check: - Was parameter [P 304] used?

 

 

 

 

 

 

 

 

 

 

 

 

- Cabling and limit switches.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F 60

 

 

Fieldbus Timeout

 

 

Serial interface (communication bus) is not

11103

bit 13

/(3)

 

 

 

 

 

 

 

O.K.

 

 

 

 

 

 

De-

 

 

 

 

 

 

 

Check: - Does a field bus module selected

 

 

 

 

pends

 

 

 

 

 

 

 

via parameter [P 4001] exist?

 

 

 

 

on

 

 

 

 

 

 

 

- Communication between control

 

 

 

 

[P 920]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system and module Nxxx-0xO.K.?

 

 

 

 

 

 

 

 

 

 

 

 

No or incomplete telegrams?

 

 

 

 

 

 

 

 

 

 

 

 

- Communication between module

 

 

 

 

 

 

 

 

 

 

 

 

Nxxx-0xand thyristor power con-

 

 

 

 

 

 

 

 

 

 

 

 

verter O.K.?

 

 

 

 

 

 

 

 

 

 

 

 

 

- Correct setting of the time inter-

 

 

 

 

 

 

 

 

 

 

 

 

val between two telegrams via

 

 

 

 

 

 

 

 

 

 

 

 

parameter [P 921]?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IV A 4 - 10

DCS 500B / DCP 500B Operating Instructions

3ADW000055R0401_DCS500B_Operating Instruction_e_d

Page 62
Image 62
DCS 500 manual IV a 4