DCS 500 manual Only if analog tacho is used as speed feedback, 12516 =, IV A 2

Models: 500

1 76
Download 76 pages 28.4 Kb
Page 31
Image 31
Only if analog tacho is used as speed feedback!

Chapter 2 - Start-Up Instructions

Only if analog tacho is used as speed feedback!

Switch ON power; start drive.

12516 = increase slowly up to 20000 (=100 % speed). DANGER: System components now energized!

12516 = increase slowly up to 20000 (=100 % speed).

Check motor voltage; if value has been set with 501, motor voltage must remain constant, or must not exceed this value.

Measure speed with manual tacho; balance maximum speed with R9, R48 or R2716.

12516 = 0

Switch OFF power, thus stopping the drive!

CAUTION! Please don't forget!

11202 = SAVE MOT1 SET

Save the altered values in the non-volatile memory!

DCS 500B / DCP 500B Operating Instructions

IV A 2 - 19

3 A D W 0 0 0 0 5 5 R 0 4 0 1 _ D C S 5 0 0 B _ O p e r a t i n g I n s t r u c t i o n _ e _ d

Page 31
Image 31
DCS 500 manual Only if analog tacho is used as speed feedback, 12516 = increase slowly up to 20000 =100 % speed, IV A 2