Chapter 2 - Start-Up Instructions

Drive must not turn!Do not preset an external reference!

1201 = 3 Panel display: ARM. AUTOTUNING

Activate the current controller's auto-tuning function.

Start the next two steps within the next 20 seconds!

Switch ON power.

DANGER: System components now energized!

Start drive.

When the display shows NOT ACTIVATED (action correctly completed), stop drive; it may happen that the unit runs armature-circuit current since e.m.f. control is active; nmin - signal (2201) value too small.

Switch OFF power!

Read out values of:

 

 

 

407 =

408 =

409 =

410 =

411 =

Use values of 409 and 410 from the first auto-tuning routine. Re-activate the field unit used by entering:

a) 505 = 1Panel display: DIODE FIELD EXCIT and install the supply fuses removed before!

or

b) 505 = 2

Panel display: FEX2 OR FEX3

CAUTION! Please don't forget!

11202 = SAVE MOT1 SET

Save the altered values in the non-volatile memory!

DCS 500B / DCP 500B Operating Instructions

IV A 2 - 11

3 A D W 0 0 0 0 5 5 R 0 4 0 1 _ D C S 5 0 0 B _ O p e r a t i n g I n s t r u c t i o n _ e _ d

Page 23
Image 23
DCS manual DCS 500B / DCP 500B Operating Instructions IV a 2