Chapter 2 - Start-Up Instructions

Only when an encoder (pulse encoder) is being used!

12104 = Content of pulse counter

If the shape of the curve corresponds to the diagram below, this means the wiring is correct and the pulses will be correctly evaluated [see also documentation entitled „Technical Data“, Chapter I/O boards].

65535

0

Fig.: Curve shape of the encoder’s pulse counter for sense of rotation "forwards“

Switch OFF power, thus stopping the drive; drive coasts.

2101 = No. of encoder pulses

As specified on the encoder's rating plate

2102 = 3 Panel display: ENCODER A+-, B+- Encoder is used for speed control.

Switch ON power; start drive.

DANGER: System components now energized!

Drive should run at 10 % of the desired speed; if possible, check with manual tacho.

Only when the e.m.f. signal is being used as speed feedback!

Drive should run at 10 % of the desired speed; if possible, check with manual tacho.

Switch OFF power, thus stopping the drive; drive coasts.

CAUTION! Please don't forget!

11202 = SAVE MOT1 SET

Save the altered values in the non-volatile memory!

DCS 500B / DCP 500B Operating Instructions

IV A 2 - 13

3ADW000055R0401_DCS500B_Operating Instruction_e_d

Page 25
Image 25
DCS 500 manual Only when the e.m.f. signal is being used as speed feedback