ATTRIBUTES

 

 

 

EXCEL 50/100/500/600/800

 

 

 

Table 19. Datapoint attributes

 

 

 

 

 

 

 

 

 

 

 

 

global datapoint

global datapoint

flexible datapoint

flexible datapoint

 

flexible datapoint (type:

 

 

(analog)

(digital)

(type: Pulse 2)

(type: feedback)

 

multi-stage)

 

 

User Address

User Address

User Address

User Address

 

User Address

 

 

Descriptor

Descriptor

Descriptor

Descriptor

 

Descriptor

 

 

Technical Address

Technical Address

Technical Address 1/2

Technical Address

 

Technical Address

 

 

 

 

 

1/2/3/4/5/6

 

1/2/3/4/5/6

 

 

Access Level

Access Level

Suppress Point

Status

 

Suppress Point

 

 

 

 

 

 

 

 

 

 

Write Protection

Write Protection

Access Level

Switching down

 

Access Level

 

 

Operating Mode

Operating Mode

Write Protection

Off phase

 

Write Protection

 

 

Value

Value

Operating Mode

Delay switch up

 

Operating Mode

 

 

 

 

 

 

 

 

 

 

Manual Value

Manual Value

Status

Delay switch down

 

Value

 

 

 

 

 

 

 

 

 

 

Engineering Unit

Alarm Type

Manual Status

Feedback Delay

 

Manual Value

 

 

Low Warning Limit

Alarm Delay

Status Text

Operating Mode

 

Status Text

 

 

 

 

 

 

 

 

 

 

Low Alarm Limit

Alarm Status

Alarm Type

Manual status

 

Active State

 

 

 

 

 

 

 

 

 

 

High Warning Limit

Point in Alarm

Trend Logging

Status Text

 

Alarm Type

 

 

High Alarm Limit

Alarm Reporting

Hours Run Log

Suppress Point

 

Alarm Reporting

 

 

Alarm Type

Trend Logging

Hours Run

Access Level

 

Trend Logging

 

 

 

 

 

 

 

 

 

 

Alarm Delay

Hours Run Log

Pulse Duration

Write Protection

 

Hours Run Log

 

 

Point in Alarm

Hours Run

Service Interval

Trend Logging

 

Hours Run

 

 

Trend Logging

Service Interval

Hours Since Serviced

Hours Run Log

 

Service Interval

 

 

 

 

 

 

 

 

 

 

Alarm Status changed

Active State

Last Changed

Hours Run

 

Hours Since Serviced

 

 

Alarm Hysteresis

Hours Since Serviced

Cycle Count

Service Interval

 

Last Changed

 

 

Trend Hysteresis

Active State Text

Suppress Alarm

Subtype

 

Cycle Count

 

 

 

 

 

 

 

 

 

 

Trend Cycle

Passive State Text

 

Hours Since Serviced

 

Suppress Alarm

 

 

Suppress Alarm

Cycle Count

 

Alarm Type

 

 

 

 

Broadcast Hysteresis

Last Changed

 

Point in Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

Suppress Alarm

 

Alarm Reporting

 

 

 

 

 

 

 

Last Changed

 

 

 

 

 

 

 

Cycle Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suppress Alarm

 

 

 