Dial Tone Detection

Parameter #

Description

Units

46

47

48

49

Maximum wait for all dial tone detection. Maximum total time1ms

OfficeJet

Series 300 will wait for any dial tone.

(1000 ms to

 

 

 

Country

Default

30000 ms)

 

 

 

United States

10000

 

 

 

 

Australia

5000

 

 

 

 

France

10000

 

 

 

 

Germany

15000

 

 

 

 

Netherlands

18000

 

 

 

 

United Kingdom

8000

 

 

 

 

India

10000

 

 

 

 

Korea

10000

 

 

 

 

China

10000

 

 

 

 

 

 

 

 

 

PSTN dial tone detect. Indicates the frequency combination

1=1

 

to identif

a PSTN dial tone.

 

2=2

 

 

 

Country

Default

3=1&2

 

 

 

United States

5

5=1or2

 

 

 

Australia

1

6=1&2or3&4

 

 

 

France

9

7=1or2or3&4

 

 

 

Germany

14

8=1&2or3or4

 

 

 

Netherlands

9

9=1or2or3or4

 

 

United Kingdom

5

10=1&2&3&4

 

 

 

India

5

11=1or2&3&4

 

 

 

Korea

5

12=1&2&3or4

 

 

 

China

5

13=1or2&3or4

 

 

 

 

 

14=1or2or3

 

 

 

 

 

 

tone

PSTN dial tone detection time minimum. Indicates the total

1 ms (100 ms

 

sequence must be present for a PSTN dial tone to be detected

15000 ms)

 

 

 

Country

Default

 

 

 

 

United States

500

 

 

 

 

Australia

1000

 

 

 

 

France

1900

 

 

 

 

Germany

2500

 

 

 

 

Netherlands

1500

 

 

 

 

United Kingdom

1000

 

 

 

 

India

500

 

 

 

 

Korea

500

 

 

 

 

China

500

 

 

 

 

PSTN dial tone minimum on time. This is the minimum duration

1 ms (50 ms

 

 

 

PSTN dial tone must be present for a cadenced sequence to be

to 20000 ms)

 

 

 

Country

Default

 

 

 

 

United States

0

 

 

 

 

Australia

0

 

 

 

 

France

0

 

 

 

 

Germany

0

 

 

 

 

Netherlands

0

 

 

 

 

United Kingdom

0

 

 

 

 

India

0

 

 

 

 

Korea

0

 

 

 

 

China

0

 

 

 

 

 

 

 

 

 

 

5-64Problem Resolution

Page 103
Image 103
HP 350, 330 manual Dial Tone Detection