COMMUNICATION ERROR CODES (Continued)

TRANSMIT ERRORS (500 level codes continued) – Code numbers not listed are not used

CODE

DESCRIPTION

COMMENTS

 

526

Irrelevant response

The response received following the DCS + training was

 

 

valid (expected CFR).

 

 

 

 

 

531

Irrelevant response

The response received following the transmission of M

 

 

EOP, EOM was incorrect. Check diagnostic bits 11 and 12.

 

 

 

 

532

DCN received

DCN was received in a response to the transmittal sign

 

 

Check diagnostic bits 11 and 12.

 

 

 

 

533

Line disconnect

Receiver sent DCN and dropped the line after waiting 3 s

 

 

onds for a received frame or the line signal was gone

 

 

than 0.2 seconds.

534No response on all retries The connection was lost either because the line was d or the receiver hung up.

535

Fallback impossible

Fallback in the transmission of post messages is not p

 

 

Remote receiver does not respond with a RTP or RTN or t

 

 

transmitter can’t retransmit. If the session is non-EC

 

 

the receiver responded RTN after the sending unit sent

 

 

page, the sending unit will train down to a slower spe

 

 

the next page. After 2400 baud fails, the unit cannot tra

 

 

down any slower and reports error code 535. In ECM mod

 

 

the error might be possible, but the sequence would b

 

 

ent (not using RTN).

536At least one page not confirmedOccurs in non-ECM mode when there are many errors on page. The page received was not readable.

541

Phone disconnected

The user has disconnected the line after the voice ses

 

 

without continuing the fax session.

 

 

 

 

542

Time-out

The T3 operator intervention timer has expired.

 

 

 

 

543

Irrelevant response

The response received after the transmission of a voic

 

 

quest to the remote sender was not a DIS.

 

 

 

 

551

DCN received

DCN was received in a response to the transmitted sign

 

 

Check diagnostic bits 11 and 12.

 

 

 

 

552

Line disconnect

Receiver sent DCN and dropped the line after waiting 3 s

 

 

onds for a received frame or the line signal was gone

 

 

than 0.2 seconds.

553No response on all retries The connection was lost with the receiver either beca line was lost or the receiver hung up.

554

Irrelevant response

The response received following the transmission of P

 

 

NULL, PPS-MPS, PPS-EOM was incorrect. Check diagnos-

 

 

tic bits 11 and 12.

 

 

 

 

555

Fallback impossible

System is unable to receive a valid ECM transmission a

 

 

baud rate.

 

 

 

 

 

 

(Continued on next page)

 

 

 

 

5-38Problem Resolution

Page 77
Image 77
HP 350, 330 manual 38Problem Resolution