COMMUNICATION ERROR CODES (Continued)

TRANSMIT ERRORS (500 level codes) – Code numbers not listed are not used

CODE

DESCRIPTION

COMMENTS

 

501

Line busy

Busy tone detected during initial handshake. “BUSY” dis

 

 

played on journal.

 

 

 

 

502

DCN received

A DCN was received in a command frame that was receiv

 

 

in response to CNG. The remote side ended the session by

 

 

sending DCN (disconnect) very early in the session setu

 

 

Between 2 HP OfficeJet Series 300s, you can cause this con-

 

 

dition by pressing STOP on the receiving unit immediate

 

 

upon seeing the “Answering...” display.

 

 

 

 

503

Line disconnect

Receiver sent DCN and dropped the line after waiting 3 s

 

 

onds for a received frame or the line signal was gone

 

 

than 0.2 seconds.

 

 

 

 

504

Irrelevant response

Command following CNG was not valid.

 

 

 

 

505

Time-out

T1 timer elapsed and no response received. “No answer”

 

 

played on journal report.

511Incompatible remote receiverReceiver is non-compatible for customizable function

512Incompatible remote receiverReceiver is non-compatible or polling was requested nied.

513Polling password incorrectYou were polled and there was no document to send.

514No documents to be polledThe polling unit does not look at the DIS which says w not have a document to poll and requests us to send way.

515

Time-out

Timer has elapsed.

 

521

DCN received

DCN was received in a response frame following the tra

 

 

phase. The remote side ended the session by sending DCN

 

 

(disconnect) during the session setup. Between 2 HP

 

 

OfficeJet Series 300s, you can cause this condition by pre

 

 

ing STOP on the receiving unit immediately upon seeing

 

 

“Connecting...” display.

 

 

 

 

522

Line disconnect

Receiver sent DCN and dropped the line after waiting 3 s

 

 

onds for a received frame or the line signal was gone

 

 

than 0.2 seconds.

523No response on all retries No response was received on all 3 attempts to establis nection with DCS.We lost connection with the receiver, because the line dropped or because the receiver hun

524

Identification received

Failure to sync with the remote unit. The line may be

 

 

tive which keeps the remote unit from seeing the DCS c

 

 

mand.

 

 

 

 

525

Fallback impossible

Fallback in modem speed is needed but impossible (for

 

 

ple: receiver supports V.29 but V.27 is needed). All attempts

 

 

to train with the remote unit have failed. The HP Office

 

 

Series 300 attempts to train at 9600, 7200, 4800 and 2400

 

 

baud.

(Continued on next page)

Problem Resolution5-37

Page 76
Image 76
HP 330, 350 manual Description Comments