Parameter #

Description

Units

138

139*

140*

141*

142*

143*

144*

145*

147

148

149*

150

151*

Print TTI header. If TRUE, the header identification will be

0

= FALSE

 

included on each fax page sent by HP OfficeJet Series 300.

1

= TRUE

 

Default value = 1.

 

 

 

 

 

 

into

Backup receive mode. If TRUE, received faxes will be received

0

= FALSE

memory if the not able to be printed out. 400K bytes of memory1

 

= TRUE

for

backup reception. This parameter is selected by the user from

 

Settings

menu.

 

 

 

Default value = 1.

 

 

 

Fax reduction. Sets the amount of reduction applied to

0

= OFF

User may

choose either OFF or ON where the amount of reduction is applied100= ON

 

based on the size of the incoming fax and media available for1(70 to 100)

 

Default value = 0%.

 

 

 

 

 

 

Beep volume. Users may select SOFT or LOUD from the Phone Setup0

= OFF

 

Default value = 1.

1

= SOFT

 

 

2

= LOUD

 

Fixed copy reduction. Users may select 100%, 95%, 90%, 85%, 80%, 75%

1

(70 to 100)

 

legal–to–letter, and 70% from the Copier Settings menu.

 

 

 

Default value = 100%

 

 

 

Scanner contrast. User selects from the FAX/Copy Contrast

0

= Light

 

Default value = 1.

1

= Normal

 

 

2

= Dark

 

 

 

 

 

FAX resolution. Controls the STANDARD and FINE resolution settings0=Standard

 

conjunction with parameter 145 to define PHOTO resolution. User 1=Fine

the

<Resolution> key.

 

 

 

Default value = 0.

 

 

 

 

 

 

 

FAX halftone. Will select PHOTO resolution if parameter 144 is set

0

= FALSE

 

selects from the <Resolution> key.

1

= TRUE

 

Default value = 0.

 

 

 

PCL portrait/ landscape orient.

0

= Portrait

 

Default value = 0

1

= Landscape

 

Speaker mode.

0

= Disable

 

Default value = 1.

speaker

 

 

1

= Enable

 

 

speaker

 

 

2

= Enable

 

 

speaker

 

 

always

 

Button beeps. User may select from the Phone Setup menu.

0

= OFF

 

Default value = 1

1

= On

 

Menu flags. Not currently used.

N/A

 

Default value = 0.

 

 

 

 

 

 

 

Remote diagnostics. Allows access to internal parameters

0

= FALSE remote

operations from the Service and Factory menu. If TRUE, access1

= TRUE

. User

may select from the Phone Setup menu.

 

 

 

Default value = 0.

 

 

 

 

 

 

 

5-92Problem Resolution

Page 131
Image 131
HP 350, 330 manual = True, = Soft = Loud