CALIBRATION VALUE SCALE

 

6

 

 

 

 

 

 

SET-UP

 

 

 

 

 

 

 

 

How to Read the Scale

640

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cut the top of this chart along the

 

 

 

 

 

620

1

 

630

 

 

 

 

dashed line.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

610

 

 

 

 

2

Enter the “Change Parameter” menu and

630

530

 

580

680

 

select parameter 200.

 

 

 

 

610

510

 

560

660

 

a) note existing value:

 

 

 

590

490

 

540

640

 

 

 

 

570

470

 

520

620

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b) enter new value:

 

 

1500

650

550

450

500

600

700

 

 

 

 

 

 

 

 

 

 

 

 

CALIBRATION VALUE SCALE

 

 

MEASUREMENT

 

 

 

 

 

 

 

 

 

 

 

 

3 Exit the Service Menu and

 

 

 

 

 

 

 

 

a) set Copy Reduction to: 100%

Moving from the left side to the right

 

 

 

 

 

 

 

 

 

 

 

 

b) set Resolution to: FINE

 

side, the scale increments by 10 for

 

 

 

 

 

 

 

 

 

 

 

each scale tick mark (20 between

4

Load this sheet (after the top portion

tick marks on the same side). The

is removed) into the FAX document

highest readable value in this

 

 

feed tray (print side down, top end

example is 640.

 

 

 

 

first).

Make one copy.

 

 

 

 

 

 

 

 

CALIBRATION

5Look at the copy and find the top most tick mark of the Calibration Value Scale which is visible.

6Determine the Calibration Value corresponding to this tick mark. See “How to Read the Scale”.

7Enter this value at parameter 200 location using the “Change Parameter” menu. Calibration is complete.

4-4Calibration and Adjustment