Parameter #

Description

Units

9

10

11

Ring envelope maximum ON time. Maximum time an entire ring

1 ms

 

present to be counted as 1 ring. The entire ring signal may

(50 ms to several ring

bursts separated by periods of silence.

10000 ms)

 

Country

Default

 

 

United States

8000

 

 

Australia

8000

 

 

France

8000

 

 

Germany

8000

 

 

Netherlands

8000

 

 

United Kingdom

8000

 

 

India

8000

 

 

Korea

8000

 

 

China

8000

 

 

Ring envelope minimum OFF time. Minimum time between ring

1 ms

where

each ring envelope may consist of a single or multiple rings

(200 ms to

time has

expired the ring count is incremented.

20000 ms)

 

Country

Default

 

 

United States

1000

 

 

Australia

1000

 

 

France

1000

 

 

Germany

1000

 

 

Netherlands

2000

 

 

United Kingdom

1000

 

 

India

1000

 

 

Korea

1000

 

 

China

1000

 

 

Ring envelope maximum OFF time. Maximum time between ring

1 ms

after

which the ring count is reset to zero. When this period of

(200 ms toexpired all

ringing is considered complete.

20000 ms)

 

Country

Default

 

 

United States

8000

 

 

Australia

8000

 

 

France

7000

 

 

Germany

8000

 

 

Netherlands

8000

 

 

United Kingdom

8000

 

 

India

8000

 

 

Korea

8000

 

 

China

8000

 

 

 

 

 

 

Problem Resolution5-53

Page 92
Image 92
HP 330, 350 manual Problem Resolution5-53